17
Using the Avant 9600
Nurse Call Feature
The Avant 9600 features a Nurse Call circuit that can be connected to a hospital
nurse call system, allowing alarm conditions to be recognized at a central monitoring
location and on the Avant 9600.
Option switch 7 allows users to select the duration output of a signal. In the DOWN
position, a one-second signal is active when an audible alarm starts and is repeatedly
sent every 60 seconds during the entire duration of the audible alarm. In the UP
position, the nurse call signal is active during the entire duration of an audible alarm.
The nurse call output signal is active when the 9600 is in Standby mode.
The Nurse Call Circuit can be used both when the Avant 9600 is plugged in and
when it is running on battery power. In addition,
the nurse call output operates at any
alarm volume setting—including when audible alarms are turned off.
Included in the Nurse Call Circuit is a switch—located on the base of the back panel
and covered by the back cover to prevent accidental toggling—that allows users to
select the Nurse Call as either Normally Open (NO) or Normally Closed (NC) relay
output.
WARNING: It is the user’s responsibility to implement the interface
between the Nurse Call system and the Avant 9600, and to
adequately test the interface between the 9600 and the Nurse
Call system to ensure that the desired function is operational.
Electrical State of Nurse Call Output
Nurse Call
Switch Position
Nurse Call
Not Active
Nurse Call
Active
Standby
Mode
Right Open Closed Closed
Left Closed Open Open
Nurse Call
Connection
RS232 Serial
Connection
Power
Connection
Nurse Call
Switch
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nonin Avant 9600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nonin Avant 9600 in the language / languages: English as an attachment in your email.

The manual is 0,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nonin Avant 9600

Nonin Avant 9600 User Manual - German - 47 pages

Nonin Avant 9600 User Manual - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info