Acceptable Types of Connector Pipe
Minimum Flue Diameter: Minimum 6”, Maximum 10”
Minimum recommended chimney height (from appliance to termination): 12’-15’
- When Using Single Wall Pipe: Install a 6-inch diameter, single wall, 24 MSG black steel or 26 MSG blued steel
connector pipe on the flue collar of the unit. The crimped ends of the pipeshould all point down. Additional sections of
single wall pipe should be fastened together with at least three sheet metal screws each section. All pipe connections
must be sealed (using high temperature silicone).
- When connecting to the factory-built ceiling support package, use the manufacturer’s transition piece, usually called
a dripless connector, to join single wall pipe to their factory-built chimney section.
- When using approved double wall pipe: Type L and listed doublewall connector pipe is acceptable. Install any
factory-built brand of pipe according to the manufacturer’s instructions. All pipe connections must be sealed.
- Chimney Connector Adapter - Use a 6-inch chimney connector adapter to connect the chimney connector up to the
chimney. The small ends of the chimney connector should all point down for a drip free installation. Secure adjoining
sections of chimney connector to each other using three sheet metal screws. Secure the connector pipe to flue collar
using three sheet metal screws. DO NOT secure chimney connector to chimney with screws.
- Connection to a factory built chimney - Your stove may be connected to a factory-built chimney conforming
to CAN / ULC – S629, Standard for 650°C Factory-Built Chimneys. All pipe connections must be sealed.
- For Reduced Residential Clearances Using Double Wall Pipe: Type L and listed double wall connector pipe is
acceptable. Install any factory-built brand of pipe according to the manufacturer’s instructions.
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nestor Martin S33 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nestor Martin S33 in the language / languages: English as an attachment in your email.

The manual is 2,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nestor Martin S33

Nestor Martin S33 User Manual - English - 48 pages

Nestor Martin S33 User Manual - Dutch, French - 25 pages

Nestor Martin S33 User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info