Be aware of the following:
Discuss the cleaning options with your chimney sweep.
If there is insufficient draught in the chimney, it may be a good idea to install the
flue pipe straight up, so as to minimise smoke migration in the actual combustion
chamber.
Avoid having any more bends than necessary, and limit the length of the flue pipe so
as not to reduce the draught.
Fresh air supply
A wood-burning stove requires air for combustion. As a result, firing a wood-bur-
ning stove will help to create a healthy climate in your house. If the house is very
tightly sealed, and particularly if there is a cooker hood or ventilation system in the
house, it may be necessary to install an air grate in the room in which the wood-
burning stove is installed. Otherwise there may not be enough draught in the chim-
ney, which may result in the stove not being able to burn properly, and smoke may
come out of the stove when the fire door is opened.
If it is necessary to install air grates, they must be positioned so that they cannot be
obstructed.
1.7 Connecting to a brick chimney
Brick a flue bushing securely into the wall, and insert the flue pipe into it. The pipe must not
extend into the actual chimney opening, but only to the inside of the chimney aperture. The
joints between the stove/pipe and pipe/wall bushing must be sealed with the glass tape pro-
vided. It is not normally necessary to seal between any pipe joints.
If the flue pipe transitions from horizontal to vertical, it is a good idea to install it with a gentle
bend so as to avoid any loss of draught.
The flue pipe must be dimensioned in accordance with national and local regulations. Morsø
recommends, however, that flue pipes be made of 2 mm sheet steel, as this will extend the
service life.
1.8 Connecting to a steel chimney
If your installation involves taking the chimney straight up and through the ceiling, you must
comply with National, Local Building Regulations or flue manufacturers instructions concern-
ing clearances to combustible materials such as walls, floor joists and ceilings. The joint be-
tween the stove flue collar and the stovepipe must also be sealed using the glass fibre rope
provided. It is important that the insulated flue system is properly supported both at ceiling
level and at roof level.
THE STOVE MUST NOT BEAR THE WEIGHT OF THE CHIMNEY SYSTEM (See chimney manu-
facturer’s instructions). Excessive weight on the stove will inhibit expansion and could lead to
damage of the stove top. Damage caused to the stove in this way would not be covered by the
manufacturers guarantee.
If a chimney fire should occur as a result of incorrect operation of the stove or prolonged use
of wet fuel, close the vents completely and contact the fire brigade.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morso 8100 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morso 8100 series in the language / languages: English, Danish as an attachment in your email.

The manual is 0,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morso 8100 series

Morso 8100 series Usermanual and installation guide - German - 20 pages

Morso 8100 series Usermanual and installation guide - Dutch, French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info