METTLER TOLEDO
8 Tiger II
GB
PLU (Price Look Up) Function
The PLU function can store 100 PLU. They can be used for frequently sold goods, where the data (prices or/and
tare* depending on the setting in factory) can be looked up by simply entering the PLU number. The default is
price only.
*Preset tare is not permitted in EU countries.
Store a PLU (unit price or/and tare)
Enter the required unit price or/and tare.
PLU
Press and hold the PLU key until a long beep is heard. In the weight display appears: “PLu”.
Enter the PLU number (between 1 and 100) and wait for approx. 2 seconds, until the scale beeps twice.
Recall a PLU (automatic search function off, refer to SET-UP, step 5)
Input the required PLU number, then press the PLU key. The stored data will appear in the display.
Recall a PLU (automatic search function on, refer to SET-UP, step 5)
Input the required PLU number, the stored data will appear in the display.
Notice: To call PLU 12, press 1 and 2 within 2 seconds, if the 2 is not pressed within 2 seconds, the PLU
number 1 will be called up.
Preset Key Function
The scale has 16 preset keys, which can store another 16 or 32 PLU and recall theses PLU directly.
Store a PLU in a preset key
Enter the required unit price or/and tare.
~ Press and hold the required M-key until a long beep is heared, then two continous beeps will be heard to
indicate the data have been stored.
Recall a PLU in a preset key
Press the required M-key, the data stored will appear in the display.
When double click function is on, referring to SET-UP, step 6, one preset key can store and recall 2 PLU. The
way to store and recall the first PLU is same as the operation in “Store a PLU in a preset key” and “Recall a PLU
in a preset key”.
Store the second PLU in a preset key (double click function is on, refer to SET-UP, step 6)
Enter the required unit price or/and tare.
Press and hold the required M-key until a long beep is heard, then press this M-key again and release it within
1 second, “L 2” will appear to show this data is stored by double-clicking M-key, and two beeps will finish the
storage.
Recall the second PLU in a Preset (double click function is on, refer to SET-UP, step 6)
Double click the required M-key within 1 second, the “L 2” will be shown in the weight display for 1 second,
then the data stored by double-clicking this M-key will appear in the display.
Fix Key Function
Normally the tare and unit price will be cleared after each weighing, with key-FIX the tare and unit price can be
fixed.
Press the key-FIX and cursor FIX will be lit, the tare and unit price will remain until new value is entered.
Press the key-FIX again to switch off the fix function.
M1 M16
FIX
ON/OFF
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mettler-Toledo Tiger II - RN10-CNRS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mettler-Toledo Tiger II - RN10-CNRS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info