Battery type
Tiger II provides alternative to use battery. You can see the left sticker in the battery holder. The
default status is that the switch is covered by the sticker, and default location of the switch is on
the NIHM side, it means to
only use rechargeable NIHM batteries of size UM1.
If you would like to use D-cell, please break the box in the middle of the sticker, and push the switch to the D-cell side,
in this status, charging function is disabled automatically.
Always make sure that all six batteries have the same capacity. Please contact your authorized dealer for more
information.
Notice:
Whenever you change the battery, please check the switch location to be sure that you chose the right battery type.
Installation
Before you install the batteries, make sure that the external power supply is disconnected. Turn the scale upside down
and lay the scale carefully on the platter. Open the battery cover by pressing the two buttons, and then install the
batteries as shown on the battery holder. Close the cover by just putting it back and pressing it to the right location.
Operation
When the scale is running on the battery power, the functionality will be same as when it is running on external power.
Additionally, the so called “Sleep” function can be used, please refers to the step-up step 2. When the scale has
activated the “Sleep” mode, simply depress any key to wake the scale.
When the power of the batteries is used, the battery cursor will light up to indicate the state of the battery.
: The battery is full or fully charged.
: Only about 2/3 power of the battery left
: Only about 1/3 power of the battery left
: The power of the battery is at a critical level. The scale will be automatically turned off when the voltage of the
battery is lower than 6V to prevent any wrong weight display.
Charging (automatically)
The automatic charging will only start when the battery capacity has dropped below approx. 5% of its capacity.
The scale allows recharging the NIHM batteries automatically and easily. To charge new NIHM batteries, please allow
between 10~15 hours, depending on the battery type selected. To charge the batteries, simply connect the scale to the
external power supply and switch the scale on.
During the charging, the battery cursor will blink. The quantity of the blocks inside the outline indicates how much
power the battery now has. When blinking stop, the batteries are fully charged.
Manually Charging
To enable you to charge the batteries at any time at your convenience, even when they are not yet below approx. 5% of
their capacity, the charging can be started manually. If the scale is connected to the external power supply and is
switched on. Simply press the key-00 and keep it depressed for approx. 3 seconds, until the battery cursor’s outline start
blinking. When the cursor has stopped blinking, the batteries are fully charged. Assuming the power is not interrupted
during recharging.
Note
The total operation time of the scale on fully charged batteries depends on the basic capacity (mAh) of the batteries. The
capacity of the NIHM batteries will reduce over the years and therefore also the total operation time of the scale. This is
not an error of the scale, but it is normal behavior of the NIHM batteries.
Batter
y
Maintenance
Switch to chose
battery type
Battery
NIHM
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mettler-Toledo Tiger II - RN10-CNRS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mettler-Toledo Tiger II - RN10-CNRS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info