598215
43
Zoom out
Zoom in
Previous page
1/68
Next page
MX 20
38
· If the leads are not short-circuited or connected to a resistance,
the display indicates an out of limits condition «1 » blinking.
· Under no circumstances should resistance be measured on a live
circuit.
· Certain precautions may be necessary to measure high resistan-
ces (40Mohms range): use of screened cables, screening of the
resistance to be measured, etc. Because of the acquisition speed
of the multimeter, the measurement may be disturbed and made
unstable by electrical or electrostatic interference.
Quick continuity check (buzzer)Quick continuity check (buzzer)
Quick continuity check (buzzer)Quick continuity check (buzzer)
Quick continuity check (buzzer)
· Set the rotary switch to the position.
· The multimeter operates on the 2kW range, and an audible signal
will be heard when the measured circuit resistance is less than
1000 W approx.
Diode checkDiode check
Diode checkDiode check
Diode check
· The diode check entails injecting a given current into the diode
junction to be tested and reading the voltage drop across the diode.
· Connect the black lead to the COM terminal and the red lead to
the VW terminal and then set the rotary switch to the position.
· The display will indicate 1.2 to 1.8V if the diode junction is reverse
biased or if the circuit is open.
· Like resistance measurements, the diode check function must not
be used on a circuit that is live.
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 20 in the language / languages: English, German, French as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info