40
· It is best to begin by selecting the highest possible range (10A)
when the order of magnitude of the current to be measured is
unknown.
· Do not connect the multimeter in series with the circuit to be
measured until the last possible moment. Then switch on the circuit
to be measured.
· If the range chosen is too high, first switch off the circuit to be
measured, then change the setting of the rotary switch, and switch
on the circuit again.
· Do not under any circumstances change the range or disconnect
the test leads while measuring: this may give rise to switching
current spikes and overvoltages which can damage the multimeter
or blow the fuses unnecessarily.
· To minimise overheating and to prevent thermal drift, measure-
ments in the high current ranges (5A and 10A) should be limited to
a few tens of seconds.
3.4.7 - MEMORY3.4.7 - MEMORY
3.4.7 - MEMORY3.4.7 - MEMORY
3.4.7 - MEMORY
· The DATA HOLD key operates the memory mode for all conven-
tional multimeter functions (voltmeter, ammeter, ohmmeter).
· Pressing the key once freezes the value displayed
· Pressing the key a second time clears the display and allows a
new measurement to be carried out.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 20 in the language / languages: English, German, French as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info