600858
13
Zoom out
Zoom in
Previous page
1/56
Next page
13
ENGLISH
8.1 Fault finding
Pump does not run:
No mains voltage.
Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
Motor overheated, motor protection
relay tripped.
Remove cause for overheating
(fluid pumped too hot? Pump
blocked by foreign objects?)
After cooling off the pump will
switch ON again.
Float switch does not switch the
pump ON.
Ensure a sufficient supply of
water.
Make sure the float switch can
move unrestricted.
Motor hums but does not start:
Pump blocked by foreign object.
Clean pump.
Pump does not pump properly:
Delivery head too high.
Observe max. delivery head (see
"Technical Specifications").
Discharge hose kinked.
Straighten discharge hose.
Discharge hose leaky.
Seal discharge hose, tighten
screw fittings.
Pump runs very noisily:
Pump primes air.
Ensure a sufficient supply of
water.
Adjust float switch correctly.
Hold pump at an angle when sub-
merging.
Pump runs continuously:
Float switch does not reach cut-out
position.
Make sure the float switch can
move unrestricted.
Set to Manual mode, unplug.
A
Danger!
Have your power tool serviced by a
qualified repair person using only
identical replacement parts. This will
ensure that the safety of the power
tool is maintained.
Contact your local Metabo representa-
tive if you have Metabo power tools
requiring repairs. See www.metabo.com
for addresses.
You can download a list of spare parts
from www.metabo.com.
The packaging of the pump can be
100
% recycled.
Worn out power tools and accessories
contain considerable amounts of valua
-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on paper
produced with elemental chlorine free
bleaching process.
9. Repairs
10. Environmental Protection
11. Technical Specifications
TP 7500Si TP 12000Si
Mains voltage V 230 1
Frequency Hz 50
Rated output W 300 600
Rated current A 1.4 2.5
Fuse protection min. (time-lag or L-type circuit breaker) A 10 10
Running capacitor F 8 10
Rated speed min
-1
2800 2800
Pump capacity max. l/h 7500 11700
Delivery head max. m 6.5 9
Delivery pressure max. bar 0.65 0.9
Immersion depth max. m 7 7
Standing water max. mm 3 3
Max. temperature of primed medium °C 35 35
Protection class IP 68 IP 68
Degree of protection I I
Insulation class B B
Materials
Pump casing
Pump shaft
Impeller
Polypropylene
Stainless steel
Noryl
Polypropylene
Stainless steel
Noryl
Power cable (HO 5 RN-F) m 10 10
Discharge port thread (AG = male) 1 1/4" AG 1 1/4" AG
Dimensions (pump casing)
Height
Width
Diameter
mm
mm
mm
285
185
227
320
190
230
Weight kg 4.2 5.1
Max. length of extension cable
at 3 x 1.0 mm
2
lead cross-section
at 3 x 1.5 mm
2
lead cross-section
m
m
60
100
60
100
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo TP 7500 SI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo TP 7500 SI in the language / languages: English, German, Dutch, Danish, French, Finnish as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info