ENGLISH
Before plugging in set the operating
mode with the Mode selector
(13):
Position A = Automatic mode
Position M = Manual mode
6.1 Automatic mode
In Automatic mode the submersible
pump is automatically started and
stopped by the integrated float switch:
The pump starts pumping when the
float switch is raised by the fluid
above the starting level (14).
The pump stops when float switch
falls to below the cut-out level (15).
A
Caution!
The float switch must be able
to move in such way that the pump
can not run dry.
6.2 Manual mode
Starting
Push Mode selector (13) up to posi-
tion M. The pump starts pumping.
A
Caution!
Do not let run pump unat-
tended in Manual mode. Risk of dam-
age by pump running dry at low fluid
levels.
Stopping
Contrary to Automatic operation the
pump does not stop running when a cer-
tain water level is reached.
Push Mode selector (13) down into
position A. The pump stops when
the float switch lowers to below the
cut-out level .
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Service and repair work other than
described here must be left to quali
-
fied specialists.
7.1 Periodic maintenance
For the pump to function perfectly at any
time periodic maintenance is required.
This also applies if the pump is used
under heavy conditions, but does not run
for extended periods of time (e.g. when
used in well drains).
Yearly service
1. Check pump casing, cables and
float switch for damage.
2. Rinse pump with clear water.
Remove persistant soiling, e.g.
algae desposits, with brush and
dishwashing liquid.
3. To flush the inside of the pump,
place it into a container filled with
clear water and switch ON briefly.
Rinsing the pump.
Always rinse the pump with clear
water when liquids were pumped
that leave residues, such as chlor
-
ous water from a swimming pool.
Cleaning the float switch
1. Set Mode selector (16) to position
"O", then press and hold the selec-
tor to unlock the float cover (17).
Remove float cover.
2. Unhook float (18) complete with
shaft (19) and clean.
3. Clean walls and floor of float com-
partment.
4. Reassemble pump.
Cleaning the intake port's cover
1. Loosen screws (20) and remove the
cover.
2. Clean impeller and all accessible
inside surfaces of the casing.
Remove any fibres which may have
wound around the impeller shaft.
Remove persistant soiling with
brush and dishwashing liquid.
3. Reassemble pump.
7.2 Pump storage
A
Caution!
Frost damages the pump and
accessories, as both always contain
water!
When there is danger of freezing
remove pump and accessories and
store in frost-free location.
A
Danger!
Prior to all servicing:
Switch OFF.
Unplug.
6. Operation
13
14
15
7. Care and Maintenance
16
17
8. Trouble Shooting
18
19
20
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo TP 7500 SI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo TP 7500 SI in the language / languages: English, German, Dutch, Danish, French, Finnish as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info