PELLET STOVES Chapter 4
INSTALLATION AND USE MANUAL
page 35
Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
On the terminal indicated by the arrow, on the housings (A) and (B)
indifferently insert the two wires of the room thermostat. These wires
must pass through the hole G predisposed on the back of the stove.
Thermostat and related electrical cables are on the user's account.
Installation by a specialised technician is advised.
On the control panel of the stove, once the thermostat is connected,
the temperature detected by the probe will continue to appear;
however, in this case the temperature set on the thermostat will be
valid.
The activation of the thermostat (on/off) on the control panel is
possible from the menu, settings, on/off option thermostat, as
explained in the diagram below.
Esc Set
< Setting >
21.0°C 21.04
OFF
Mode:AUTO Menu
Temp:22°C Fan:A
Esc Set
< Setting >
Esc Set
< Thermostat >
Esc ON OK
< Thermostat >
4.7.4. Automatic mode with AUTO-ECO
This mode changes stove operation in automatic mode. Upon
reaching the temperature set by the user, the stove goes to power 1
for a short period of time. Then, if the temperature remains constant
and above the set temperature, it shuts down. The stove comes back
on automatically only when the room requires heat again, but not
before a period of time has passed for the stove to cool off. This option
is advisable only if the stove works in highly insulated rooms or where
there is low heat dispersion over time.