B
4.7.3.1. Room sensor
The room sensor (B) is placed behind the stove near the switch. You
are advised to extract the room sensor in a way that this comes out as
in figure (about 10 cm). In this way it does not detect the temperature
of the stove. It is advisable to do this operation during installation,
since before extracting the probe (B) it is necessary to take off the
clamp (C) that keeps it connected; operation possible by working inside
the stove thus without the sides. To extract the probe (B) it is
necessary to unscrew the protection cap (A) and slowly pull the probe
(B). After extracting the probe (B) sufficiently, close the protection cap
(A) again.
ATTENTION! Once the clamp that binds the probe
wire is taken off, avoid it coming into contact with the
hot parts of the stove.
4.7.3.2. External environment thermostat
connection
It is possible to connect the stove to an external thermostat. To make
this connection it is necessary to acquire the interface D (optional) that
is connected to the motherboard (E) of the stove on the manifold (F) as
indicated in the diagram below and in pag.53 par.7.
E
D
F
A
B
Fig.9 - Interface for the
environment thermostat
A = PROTECTION CAP
B = PROBE (FLUSH)
C = CLAMP
D = INTERFACE FOR
EXTERNAL THERMOSTAT
E = MOTHERBOARD
F = CONNECTOR FOR
INTERFACE CONNECTION
G = HOLES FOR CABLE
OUTLET
Fig. 8 - Motherboard (internal
stove)
Fig.7 - Room temperature sensor