27MAXDATA Server PLATINUM 3200 I M6
Light-Guided Diagnostics
The server board contains diagnostic LEDs to help you identify failed and failing components and to
help you identify the server from among several servers. Except for the ID LED, the status LED, and
the +5-volt standby LED, the LEDs turn on (amber) only if a failure occurs.
Figure 22. Diagnostic LEDs
Callout LED Function
A.
B.
C.
D.
Bit 3 LED
LSB LED
Bit 2 LED
MSB LED
POST LEDs. The sequence of lit POST LEDs is used to identify
specific errors that might occur during the boot process. The LED
code will help technical support to identify possible problems.
E. Status LED The status LED indicates whether a system is operating
correctly, has experienced a minor fault, or a major system error.
This LED shows the same status as the front panel Status LED.
F.
ID LED This LED can be turned on and off either by pressing a chassis
button or by using system management software. This LED is
useful when the system is grouped with several systems, such
as in a rack, and you need to easily find the system to perform
maintenance on it.
G. System fan 6 fault LED This LED indicates a fault has occurred with system fan 6. See
your server chassis documentation for instructions to replace
the fan.
U
S
T
E
F
G
H
R
B
A
D
C
I J K L M N O P
Q
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Maxdata platinum 3200 i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Maxdata platinum 3200 i in the language / languages: English as an attachment in your email.

The manual is 1,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info