Rev 2.2 14
NCC Config NCC Interface
Using the LCD/Keypad Interface to change the IP of the
receiver for communication with the Web GUI Interface
The LCD control panel can be used to configure the IP address of the Ethernet interfaces. Once you configure a
Ethernet interface to match your network’s subnet, you can then can use the receiver's Web GUI for status and control
(see later sections in this chapter). To change the IP address of an interface using the LCD/Keypad Interface, perform
the following steps:
1. Use the Up or Down arrow buttons on the control panel until you get to the interface (e.g. Eth0 or Eth1) menu
that you wish to change (see Table 1- 2 for a layout of the menu items).
2. Hit the green check mark button on the control panel to enter the Eth0 or Eth1 configuration menu. Once in
the configuration menu you will see the interfaces IP Address menu.
3. To edit the IP address, you need to press the green check mark button on the control panel again, and this
will bring you into the edit mode. Once in edit mode, you will see a flashing cursor over the first character of
the IP address. Now use the Up arrow button to increment the numerical value, or the Down arrow button to
decrement the numerical value. Use the left and right arrow buttons to move the cursor left and right, so that
you can adjust every value of the IP address to be on your network’s subnet.
4. Once you have set your desired IP Address, press the green check mark button to accept the changes.
When the change has been accepted, the flashing cursor will disappear.
5. If you wish to change the netmask at this point you need to press the right arrow button on the control panel.
This will bring you to the Netmask configuration menu. The default netmask is 255.255.255.0 which is for a
“class C” network. To change the netmask, hit the green check mark button to enter the edit mode and then
use the arrow buttons as described above to change the netmask. Save the changes by pressing the green
check mark button.
Using the LCD/Keypad Interface to Setup the Carrier
Parameters of Your Receiver
The LCD control panel can be used to set the RF Carrier parameters of the receiver, so the receiver will lock to your
DVB satellite feed. To do this, perform the following steps:
1. Press the up arrow or down arrow until you get to the Carrier menu you desire, either Carrier A or Carrier B
(see Table 1- 2 for a layout of the LCD menu items).
2. Press the green check mark button on the carrier menu you that wish to edit. You will now be in the
Modulation Standard menu. (Note: Modulation Standard Menu is not available on the SFX2103 or SFX3103
series receivers). If you press the green check mark button again, you will be in the edit mode for the
Modulation Standard.
3. Press the up or down arrow to select either DVB-S or DVB-S2. Then press the green check mark button to
accept the changes. When the change has been accepted, the square bracket will disappear.
4. Now press the right arrow button to enter the Frequency menu. Press the green check mark button to enter
edit mode and a flashing cursor will appear over the first character of the frequency. Use the up or down
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Max SFX Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Max SFX Series in the language / languages: English as an attachment in your email.

The manual is 4,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info