USERS MANUAL SOLADIN 600 ENGLISH
Operation
After installation the Soladin will switch on
automatically if solar irradiation is sufficient. The
Soladin operates automatically: there is no need for
adjustment or operation.
The Soladin has no ON/OFF switch; remove the AC
socket from the AC-outlet to switch it off. Do not
disconnect the MultiContact plugs during operation
of the Soladin!
No specific maintenance is required. If necessary,
use a soft clean cloth to clean the Soladin. Never
use any liquids, acids and/or scourers.
Decommissioning
First remove the AC plug from the wall socket
before you disconnect the MultiContact plugs.
Now the Soladin can be demounted in a safe way:
1. Push on the lower tab of the mounting bracket to
release the mounting lock.
2. Lift the Soladin upwards for approximately 1 cm.
3. Move the Soladin straight from the wall
Guarantee terms
Mastervolt guarantees that this product was built
according to the legally applicable standards and
stipulations. During production and before delivery
all products are exhaustively tested and controlled.
If you fail to act in accordance with the regulations,
instructions and stipulations in this user’s manual,
damage can occur and/or the product will not fulfill
the specifications. This may mean that the
guarantee will become null and void.
The guarantee period is 5 years.
Liability
Mastervolt cannot be held liable for:
Possible errors in this included manual and the
consequences of these.
Use that is inconsistent with the purpose of the
product.
Summarized specifications Soladin 600 (refer to page 30 for extended specifications)
Maximum PV power: 700 Wp
MPP voltage: 45-125 V DC
Maximum input voltage U-oc @ -10°C: 155 V DC
Maximum MPP current: 8 A DC
PV module Power One string Two strings in parallel**
75 Wp 4 - 6 in series 4 in series
100 Wp 4 - 6 in series --
125 Wp 4 - 5 in series --
36 cells
U
oc
= 28V*
U
mpp
= 18V*
150 Wp 4 (5) in series --
75 Wp 3 - 4 in series 3 - 4 in series
100 Wp 3 - 4 in series 3 in series
125 Wp 3 - 4 in series --
150 Wp 3 - 4 in series --
54 cells
U
oc
= 32V*
U
mpp
= 27V*
175 Wp 3 - 4 in series --
75 Wp 2 - 3 in series 2 - 3 in series
100 Wp 2 - 3 in series 2 - 3 in series
125 Wp 2 - 3 in series 2 in series
150 Wp 2 - 3 in series 2 in series
72 cells
U
oc
= 43V*
U
mpp
= 36V*
175 Wp 2 - 3 in series 2 in series
* Approximate value; refer to the specifications of the manufacturer
** Configuration for one string is stated. Use MultiContact branch connectors to connect two strings in parallel.
MultiContact part numbers: PV-AZS4 (positive) and PV-AZB4 (negative)
Table 3: Typical string configurations for the Soladin 600
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Soladin 600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Soladin 600 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info