ENGLISH USERS MANUAL SOLADIN 600
LED indicator
The operation mode of the Soladin is displayed by
means of a LED indicator at the front side of the
housing. In normal operation it flashes yellow: the
longer the LED illuminates yellow, the more power
is converted.
If the irradiation of the PV-modules is insufficient, for
instance at night, the Soladin switches off
automatically. When switched off, the LED indicator
is off.
Failures
As long as the indication LED isn’t illuminated red,
no failure is detected: the Soladin is operating
normally. If an error occurs, it is detected by the
apparatus itself: the LED indicator turns red. See
table 2.
Consult an installer, if you cannot solve the problem
by means of the table below.
NOTE: during sunrise or sunset a low Solar
voltage is detected by Soladin, indicated by
a red blinking LED indicator. This is a normal
situation
Indication of the LED Meaning What to do?
LED is off
Insufficient irradiation Nothing. The Soladin operates normally, but irradiation of the PV
modules is insufficient (for instance during night time)
LED is off
No power from the
PV modules
Consult an installer if the LED indicator is off during daytime.
The wiring between the PV modules and the Soladin might be
defective. Check for loose connections or incorrect polarity.
Yellow blinking
Normal operation Nothing. The Soladin operates normally. The longer the LED
illuminates yellow, the more power is converted.
Slow blinking long red
pulses
Reclosure time Nothing. After the Soladin was (re)connected to the AC grid, it checks
the quality of the AC grid before it starts operating normally. This may
take up to 5 minutes.
Fast blinking long red
pulses
Restart time lag Nothing. A system check is carried out during sunrise. This may take
up to 15 seconds before the Soladin starts operating normally.
▬▬▬▬▬▬▬▬
Uninterrupted red
No grid voltage Plug the AC-plug of the Soladin into the wall socket; check the fuse in
the meter cupboard.
Red blinking 1 time
Solar voltage too low Nothing; normal condition during sunrise and sunset.
Consult an installer if the problem remains while irradiation of the PV
modules is sufficient.
Error in the PV installation. Are the specifications of the PV modules
in accordance with the Soladin?
Red blinking 2 times
Solar voltage too
high
Consult an installer. Error in the PV installation. Are the specifications
of the PV modules in according with the Soladin?
Red blinking 3 times
AC grid voltage too
high
Check the grid connection.
Red blinking 4 times
AC grid voltage too
low
Check the grid connection.
Red blinking 5 times
Grid frequency too
high or too low
Check the grid connection.
Red blinking 6 times
Internal temperature
too high
Air flow of the Soladin may not be obstructed. If the problem remains,
switch off the Soladin by removing the AC-plug from the wall-socket
and consult an installer.
Red blinking 7 times
NTC error Consult an installer for repair of a defective safety device in the
Soladin.
Table 2
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Soladin 600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Soladin 600 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info