J. Test instructions
Cause for error
• No voltage
• Thermal overload protection in
transformer is active.
• Control unit defective
• Static current circuit
(operating elements)
is interrupted.
• Photocell defective
• Photocell interrupted
• Electronic aerial not connected
or wrong installation.
• Wrong programming of hand
transmitter coding.
• Empty battery
• Door is too sluggish or is
blocked.
• Power limit is set too
sensitively.
• Photocell programmed but
not connected.
• rpm sensor defective.
• Door is too sluggish.
Error message
• Control light VOLTAGE
does not light up.
• Control light
MALFUNCTION is flashing /
error No. 36.
• Control light
MALFUNCTION is flashing /
error No. 6 or 15
• Control light IMPULSE
does not light up when
giving impulse by hand
transmitter.
• Control light
MALFUNCTION is flashing /
error No. 10 or 28
• Control light MALFUNCTION
is flashing / error No. 15.
• Control light
MALFUNCTION is flashing /
error No. 9.
Error
• Error
• No reaction on
impulse
• Photocell
• Remote control
• Power limit
- max. power
- learning power
• Door can only be
opened.
• Operator only starts
to run shortly.
English Page 13
D. Installation
GB
• Screw the lintel joining plate (A) with boom to the top door frame, lintel
or ceiling, so that the upper edge of the door leaf lies approx. 10 mm below
the horizontal downward edge of boom - measured from the highest point
of the opening course (see as well point 3) (fig. D.16).
• Put the motor unit on a trestle or another suitable object until it is fixed later
to the ceiling.
Fitting the adapter arm:
• Screw the support bracket (B) to the upper door edge using 6 self-tapping
screws (Drill ø 5 mm) (fig. D.17).
• Centre of support bracket equals to the centre of boom.
• Put adapter arm (C) into support bracket (B) (fig. D.18).
• Screw it to the door cross strut (E) using two angle plates (D) (fig. D.18).
Drill ø 5 mm in the door cross strut (4x)
Drill ø 7 mm in the adapter arm (2x)
• Screw the angle plates to the adapter arm using two screws M6 x 10 and
hexagon nuts.
• Insert linking bar (G) with bolt (J) into the carriage (F) (fig. D.19).
• Fix it with 2 screws.
• Open door fully
• Connect linking bar (G) with the adapter arm (C) (fig. D.19).
• Observe the indicated measurements.