D. Installation
Garage door operator for retractable up-and-over door
Required accessories:
• Adapter arm Special 102, Art.-No. 563 828
• Photocell Special 613, Art.-No. 153 550
• Photocell Special 614, Art.-No. 152 675
• 2-wire photocell, Art.-No. 47 816
These are not part of the supply package Comfort 257.
10
Advice!
Remove the door locks or put them out of operation!
Attention!
In case the upper door lamella does not contain any stiffening
plates or reinforcement straps (e.g. with one-wall doors):
Use additionally door connector attachment Special 111,
Art.-No. 47 574 (not part of the supply package, compare Fig. D 15).
In the other case please only use the door connector elements,
because there is enough stability due to the stiffening.
Advice!
Remove the door locks or put them out of operation!
• Insert the door link (E) with bolt (G) into the carriage (F).
• Fix it with 2 screws.
• Connect door link and door link bracket.
GB
English Page 81
J. Test instructions
Remedies
• Check voltage.
• Check all fuses and plug connections to power.
• Have motor aggregate cooled down.
• Have control unit checked.
• Put short-circuit plug into the socket.
• Connect stop button.
• Remove obstacle.
• Have photocell checked.
• Connect aerial or align it again.
• Program coding again.
• Insert new battery (3V CR2032).
• Maintain door system (grease it or similar) or bring the door into a movable condition.
• Set power limit less sensitive.
• Increase offset learned power limit (2
nd
programming level/ Menu 4).
• Connect photocell or re-program the operator.
• Have the operator checked.
• Check door.