Extension Cords
To avoid voltage drop, power loss, and overheating of the
motor, use extra air hose instead of an extension cord.
Low voltage can cause damage to the motor.
If an extension cord must be used:
Make sure the extension cord is in good condition.
Please see the chart below for the MINIMUM extension cord gauge requirements:
Piping
Plastic or PVC pipe is not designed for use with
compressed air. Regardless of its indicated pressure
rating, plastic pipe can burst from air pressure. Use only
metal pipe for air distribution lines. If a pipe line is
necessary, use pipe that is the same size, or larger than,
the air tank outlet. Piping that is too small will restrict the
flow of air. If piping is over 100 feet long, use the next
larger size. Bury underground lines below the frost line
and avoid pockets where condensation can gather and
freeze. Apply pressure before underground lines are
covered to make sure all pipe joints are free of leaks.
DANGER:
Improper grounding can result in electrical shock. Do not
modify the plug that has been provided. If it does not fit
the available outlet, the correct outlet should be installed
by a qualified electrician.
OPERATING PROCEDURES
Daily Start-up Checklist
CONNECTING HOSES
WARNING:
Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose
whip.
Losing control of the hose may result in personal
injury and property damage.
1. Before attaching air hose or accessories, make sure
the pressure switch lever is set to “OFF” and the air
regulator or shut-off valve is closed. Ensure
compressor is disconnected from the mains supply.
2. Attach hose and accessories. Too much air pressure
causes a hazardous risk of bursting. Check the
manufacturer's maximum pressure rating for air tools
and accessories. The regulator outlet pressure must
never exceed the maximum pressure rating.
3. Turn the pressure switch lever to “ON/AUTO” and
allow tank pressure to build. Motor will stop when tank
pressure reaches “cut-out” pressure.
4. Open the regulator by turning it clockwise. Adjust the
regulator to the correct pressure setting. Your
compressor is ready for use.
5. Always operate the air compressor in well-ventilated
areas; free of gasoline or other solvent vapors. Do not
operate the compressor near the spray area.
When you are finished:
DISCONNECTING HOSES
WARNING:
Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose
whip.
Losing control of the hose may result in personal
injury and property damage.
6. Set the pressure switch lever to “OFF”. Ensure
compressor is disconnected from the mains supply.
7. Using the air tool or accessory, bleed the tank
pressure down to zero.
8. Remove the air tool or accessory.
9. Drain water from air tank by opening drain cock valve
on bottom of tank. WATER WILL CONDENSE IN THE
AIR TANK. IF NOT DRAINED, WATER WILL
CORRODE AND WEAKEN THE AIR TANK CAUSING
A RISK OF AIR TANK RUPTURE.
Note:
If drain valve is plugged, release all air pressure. The
valve can then be removed, cleaned, then reinstalled.
10. After the water has been drained, close the drain
valve. The air compressor can now be stored.
WARNING:
Drain Air Tank Properly. Improper draining of the air
tank can result in corrosion and possible bursting of
the tank. Tank bursting could lead to personal injury
and property damage.
Amp Rating Range (220 - 240 V)
Total Length of Cord in Meter
10 m
25 ft.
15 m
50 ft.
20 m
75 ft.
30 m
100 ft.
50 m
150 ft.
60 m
200 ft.
0 - 5 A 1.5 mm
2
1.5 mm
2
1.5 mm
2
2.5 mm
2
4 mm
2
4 mm
2
5.1 - 8 A 1.5 mm
2
1.5 mm
2
2.5 mm
2
4 mm
2
4 mm
2
4 mm
2
8 - 12 A 2.5 mm
2
2.5 mm
2
4 mm
2
Not Recommended
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Makita AC310H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Makita AC310H in the language / languages: All languages as an attachment in your email.

The manual is 5,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info