Word256, Header/Word, or Header/Word256 the displayed sample rate must
match the rate of the incoming clock being used for synchronization. This
will ensure the correct sample rate is stored in the file’s WAV header, and that
audio will playback at the correct sample rate.
Digital Format Allows selection of either AES/EBU or S/P DIF formats for Digital
In and Digital Out.
Digital Mode – Selects the mode for the Sample Rate Converter on the Digital Input.
SRC On – Default. The sample rate converter is on.
SRC Off: Clock Synchronous Turns off the sample rate converter and indicates
that the digital input and digital output clocks are synchronous. This mode is
useful when the digital output is feeding the digital input either directly or
through an external device with no sample rate converter.
SRC Off – The sample rate converter is off. When in this mode the Sample Clock
Source must be set to Digital. Use this mode when recording non-audio formats
such as Dolby Digital, DTS or others formats that require bit-perfect transfers.
SRC On: Digital Out The sample rate converter is turned on, but it is used by
the Digital Output instead of the Digital Input. The Digital Input sample rate
will determine the actual rate of the Digital Output. This mode is useful when
sending audio to external equipment at a different rate than it was recorded.
Transmit Only – Disables the Digital Input and the sample rate converter. Used
for testing purposes only.
Digital Input Status – Displays real-time status of the digital input, updated 4 times a
second.
Digital In Rate – Displays the measured rate of the incoming digital signal.
SRC Ratio – Indicates the sample rate conversion ratio in SRC On mode.
Digital In Mode – Displays real-time status of the digital input. Professional status
is generally associated with an AES/EBU signal, and consumer status is
generally associated with an S/P DIF signal.
Analog Trim – Sets the nominal analog input and output levels for the Lynx L22 to
either +4dBu or -10dBV. Two controls are provided, each for a pair of inputs and
outputs.
Frequency Counters – Displays the real-time clock frequency for the following sources:
L/R Clock – Left/Right Clock, which is the currently selected sample rate.
Digital Input – This is the same clock as the Digital In Rate above.
External – Clock signal from the SYNC IN connector on the L2Sync cable.
Header – Clock signal from the CLOCK IN header connector.
LStream 1 – Clock signal from the LStream port on the L2Sync connector.
LStream 2 – Clock signal from the LStream port on the board mounted header.
PCI Bus – The speed of the PCI Bus of the host computer.
Mixer Reference
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lynx L22 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lynx L22 in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info