693399
49
Zoom out
Zoom in
Previous page
1/58
Next page
lares 4.0 PROGRAMMING MANUAL
49
rev. 0/2018
Type: Reader
The subtypes available are:
• Green LED: sends a message when the green LED is selected on the reader.
• Red LED: sends a message when the red LED is selected on the reader.
• White LED: sends a message when the white LED is selected on the reader.
• Blue LED: sends a message when the blue LED is selected on the reader.
• Yellow Led: sends a message when the yellow LED is selected on the reader.
Type: Communication
The subtypes available are:
• Start of communication: sends a message when the control panel starts a PSTN/GSM/e.mail call, etc.
• Communication failure: sends a message when the control panel fails a PSTN/GSM/e.mail call etc.
• Incoming call: sends a message when the control panel receives a call.
• C-ID communication performed: sends a message when the control panel makes a call using the Contact-ID protocol.
• C-ID communication performed: sends a message when the control panel makes a call using the Contact-ID protocol.
• SIA communication executed: sends a message when the control panel makes a call using the SIA protocol.
• SIA communication failure: sends a message when a call made using the SIA protocol was unsuccessful.
The "entity" section indicates the recipients who receive the call. For example, if in "entity" we have selected the office
user (previously programmed on the "Users" page) and subtype "failed communication ", the control panel will send a
message (to the recipients in the "contact list" ) with an event of failed communication if the call to "office" fails.
Type: Power supply
The subtypes available are:
• Low power supply: sends a message when power is missing on the "lares 4.0" control panel, the wireless duo repeater
or the "opis" power supply station.
• Power recovery: sends a message when power is restored on the "lares 4.0" control panel, the wireless duo repeater
or the "opis" power supply station.
• Low battery: sends a message when the battery voltage drops below the threshold (<11V) (in the absence of the
network)
• Low battery reset: sends a message when the battery voltage is restored following the return of the 230V mains
voltage.
• Battery fault: sends a message when the "lares 4.0" control panel, the imago siren, a wireless device and the "opis"
power supply station fail the battery test.
• Low output: sends a message when the voltage supplied by the "lares 4.0" control panel falls below the threshold
(<14.4V), or when the "opis" power supply station falls below the threshold (<13.1V).
• Low output reset: sends a message when the voltage supplied by the "lares 4.0" control panel is restored above the
threshold value (> 14.4V) or when the voltage supplied by the "opis" power supply station is reset above the threshold
value (> 13.1V).
• Faulty battery charger: sends a message when the power supply of the "lares 4.0" control panel or the "opis" power
supply station fails and does not manage to supply the necessary current to the system.
• Battery charge reset: sends a message when the power supply of the "lares 4.0" control panel or the "opis" power
supply station returns to normal operation or it is replaced.
• Fuse Fault: sends a message when the fuse on the "lares 4.0" control panel or the "opis" power supply station is
detected ( e.g. due to a short circuit).
• Fuse failure reset: sends a message when the fuse on the "lares 4.0" control panel or the "opis" power supply station
restores its operating condition.
Note: if the CPU window appears in the entity window, the events that generate the communication refer to the
"lares 4.0" panel.
49


Need help? Post your question in this forum.

Forumrules
1

Forum

ksenia-lares-4.0

Reset search

  • Hi
    We have a message peripherals lost. What does this mean? Submitted on 24-7-2021 at 08:15

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ksenia Lares 4.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ksenia Lares 4.0 in the language / languages: English as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info