44
Type: Partition
• Alarm: runs the scenario when the partition generates an alarm event.
• Arming mode: runs the scenario when the partition is inserted.
• Tamper: runs the scenario when the partition generates a tamper alarm.
• Switching-off: runs the scenario when the partition is switched off.
• Bell: runs the scenario when the bell is activated.
• Bell end: runs the scenario when the bell is deactivated.
• Round: runs the scenario when, following switch-off, the round time has begun.
• Round end: runs the scenario when the round time has ended,
• Entry time: runs the scenario when the entry time starts when the partition is armed.
• Entry time end: runs the scenario when, after activation, the entry time ends.
• Output time: runs the scenario when, at the time of system arming mode, the output time begins
• Output time end: runs the scenario when, at the time of system arming mode, the output time ends; the plant is now
inserted.
• Negligence: runs the scenario when the negligence time ends (if programmed in the "Partitions") page
• Failure to insert: runs the scenario when the control unit aborts the entry (e.g. area open during arming mode and the
scenario that manages the entry has the EN5013 compatible or manual exclusion attribute).
Type: Output
The subtypes available are:
• Activation: runs the scenario when the output is activated (manually by APP or via an event e.g. scenario).
• Deactivation: runs the scenario when the output is deactivated (manually by APP or via an event e.g. scenario).
Type: Peripheral
The subtypes available are:
• Tamper (BUS): runs the scenario when a BUS device generates a tamper alarm (e.g. opening of an ergo keypad).
• Tamper recovery (BUS): runs the scenario when tamper on the BUS device is restored.
• Tamper (wls): runs the scenario when a wireless device generates a tamper alarm (e.g. opening of the Poles lid)
• Tamper recovery (wls): runs the scenario when the tamper on a wireless device is restored.
• Disappearance (BUS): runs the scenario when a BUS device is no longer detected by the control panel (e.g. cable cut or
peripheral fault).
• Disappearance recovery (BUS): runs the scenario when the device returns and is detected by the control panel
(e.g. device operation reset or BUS wiring reset).
• Disappearance (wls): runs the scenario when the control panel no longer receives periodic communication from some
wireless devices.
• Disappearance recovery (wls): runs the scenario when the control panel returns to receive the periodic
communication of a previously lost wireless device.
Type: Keypad
The subtypes available are:
• Key 0: runs the scenario when the (0) key on the keypad is pressed.
• Key 1: runs the scenario when the (1) key on the keypad is pressed.
• Key 2: runs the scenario when the (2) key on the keypad is pressed.
• Key 3: runs the scenario when the (3) key on the keypad is pressed.
• Key 4: runs the scenario when the (4) key on the keypad is pressed.
• Key 5: runs the scenario when the (5) key on the keypad is pressed.
• Key 6: runs the scenario when the (6) key on the keypad is pressed.
• Key 7: runs the scenario when the (7) key on the keypad is pressed.
• Key 8: runs the scenario when the (8) key on the keypad is pressed.
• Key 9: runs the scenario when the (9) key on the keypad is pressed.
44


Need help? Post your question in this forum.

Forumrules
1

Forum

ksenia-lares-4.0

Reset search

  • Hi
    We have a message peripherals lost. What does this mean? Submitted on 24-7-2021 at 08:15

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ksenia Lares 4.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ksenia Lares 4.0 in the language / languages: English as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info