693399
42
Zoom out
Zoom in
Previous page
1/58
Next page
rev. 0/2018
lares 4.0 PROGRAMMING MANUAL
42
To delete a single action (e.g. to delete the exclusion of zone 1 shown in the example), click on the action you want to
delete and then on the (
) symbol.
By clicking on an action and the arrows next to the (
) symbol, you can move the action up and down.
The types of notification are listed below the <“ Subtypes”:
Type: Zone
The subtypes available are:
• Zone exclusion: a previously included zone is excluded.
• Zone inclusion: a previously excluded zone is included.
• Zone switching: if this option is enabled, a previously excluded zone is included and vice versa.
Note: this subtype has no effect on zones with the "non-excludable" attribute.
Type: Output
The subtypes available are:
• Output activation: the output is activated.
• Output deactivation: the output is deactivated.
• Output switching: a previously activated output is deactivated and vice versa.
Note: this subtype also affects outputs with the "unmanaged (local)" and "unmanaged (remote)" attributes.
If an output is programmed with the "with PIN (local)" or "with PIN (remote)" attribute, it will be managed by the
scenario without requiring a PIN.
Type: Arming mode
The subtypes available are:
• Compatible with EN50131: if the system is not ready, it will not switch on and the "Failure to insert" event is
generated.
Note: if there is an open area with the "excludable" and "non-excludable" attributes, at the time of arming mode it
will be shown open on the keypad, but it cannot be excluded. As a result, the system cannot be inserted.
Zones with the "self-exclusion" attribute, if opened during arming mode, will be excluded and will not generate
alarms even if they return to rest: they will be reincluded when they are switched off.
Zones with the "with reinclusion" attribute, if opened during arming mode, will be excluded and will not generate
alarms. If they go back they will be reincluded and will, therefore, be ready to generate an alarm.
• Manual exclusion: if the system is not ready, the list of open zones will be shown with the possibility of manual
exclusion.
Note: if, upon arming mode, there is an open area with a "non-excludable" attribute, it will be shown on the keypad
but it cannot be excluded.
Zones with the "self-exclusion" attribute, if opened during arming mode, will be excluded and will not generate
alarms even if they return to rest: they will be reincluded when they are switched off.
Zones with the "with reinclusion" attribute, if opened during arming mode, will be excluded and will not generate
alarms. If they go back they will be reincluded and will, therefore, be ready to generate an alarm.
Zones with the "exclusion" attribute, at the time of arming mode, are shown on the keypad and cannot be excluded.
• Alarm forced: if the system is not ready, it is inserted and an alarm is generated.
Note: if there is an open area with the "not excludable" attribute at the time of arming mode, this zone will not be
excluded and an alarm will be generated.
The same applies to areas with the "excludable" attribute (however, these areas will not be self-excluded).
Zones with the "self-exclusion" attribute, if open during arming mode, will be excluded and will not generate alarms
even if they return to rest: they will be reincluded when they are switched off.
Zones with the "with reinclusion" attribute, if opened during arming mode, will be excluded and will not generate
alarms. If they go back they will be reincluded and will, therefore, be ready to generate an alarm.
42


Need help? Post your question in this forum.

Forumrules
1

Forum

ksenia-lares-4.0

Reset search

  • Hi
    We have a message peripherals lost. What does this mean? Submitted on 24-7-2021 at 08:15

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ksenia Lares 4.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ksenia Lares 4.0 in the language / languages: English as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info