683161
121
Zoom out
Zoom in
Previous page
1/196
Next page
5 Turn the Tuning control and align the “Current”
frequency as the frequency point for Program Slow
Scan.
6 Press any of the function keys (F2 [POINT 1] to F6
[POINT 5]) to configure the center point of the
preferred frequency range to perform Program
Slow Scan.
Pressing and holding the key clears the frequency point that
is stored.
Pressing and holding F7 [(CLR ALL)] clears all the
frequency points.
7
Press F1 [ ] to exit the Program Slow Scan
screen.
The display returns to the Memory Channel List screen.
8 Press [ESC] to exit the Memory Channel List screen.
Pressing a function key (F2 [Point 1] to F6 [POINT 5])
that already contains a frequency point overwrites the
frequency point with the new input.
When configuring a frequency point, frequencies that are
smaller than 10 Hz are rounded off.
Configuring the Segment for Program Slow Scan
The frequency switching interval during Program Scan slows down
in the preconfigured segment that contains frequencies before and
after the frequency point for Program Slow Scan.
Configure in Menu [4-03]
Program Slow Scan
Range
Setting Value 100/ 200/ 300 (default)/ 400/ 500 [Hz]
For example, when 500 [Hz] is selected, the frequency
switching interval is extended to a range of ± 500 Hz from
the frequency point.
Scan Hold
While Program Scan (VFO Scan) is performed in a mode other
than FM, changing the frequency by turning the Tuning or [MULTI/
CH] control pauses the scan operation for 5 seconds.
Signals can be received temporarily without stopping the scan
operation.
Configure in Menu [4-04]
Scan Hold
Setting Value Off (default)/ On
When Scan Hold is set to “On”, signals are received with
Program Scan paused for 5 seconds.
Memory Scan
Memory Scan allows the registered memory channel to be
automatically switched at a specific time interval for scanning.
There are 2 types of Memory Scan modes. All-channel Scan
performs scan on all the memory channels that are registered with
operating data, while Group Scan performs scan on a selected
group among the memory channels.
Performing Memory Scan
1 Press [M/V] to switch to the memory channel mode.
2 Press F5 [SCAN] to start memory scan.
Turning the [MULTI/CH] control allows the scan channel to
jump rapidly to the next or previous channels.
Pressing F5 [SCAN] again or pressing [ESC] ends Memory
Scan.
The scan direction is fixed at the ascending order.
The frequency switching interval during Memory Scan is
400 ms. However, when a CTCSS tone is received in the
FM mode, the frequency switching interval is extended
to 600 ms. During Memory Scan, “SCANNING” is
displayed instead of the scan speed.
Configuring All-channel Scan and Group Scan
1 Press [M/V] to switch to the memory channel mode.
2 Press and hold F5 [SCAN] to display the Memory
Scan group screen.
.
3
Press F2 [ ] or F3 [ ] to select a memory
group.
4
Press F4 [ ] or turn the [MULTI/CH] control to
select whether to start scanning of the memory
channels belonging to a memory group.
Pressing F4 [ ] each time selects (performs scan) or
deselects (does not perform scan) the checkbox.
When performing All-channel Scan, select the checkboxes
for all the memory groups.
Pressing F6 [SEL.ALL] selects the checkboxes for all
memory groups.
Pressing F7 [CLR.ALL] deselects the checkboxes for all
memory groups.
Memory channels are classified into memory groups as
follows. The classification of the memory groups and
channels cannot be altered.
Group
Memory
Channel
Group
Memory
Channel
0 00 to 09 6 60 to 69
1 10 to 19 7 70 to 79
2 20 to 29 8 80 to 99
3 30 to 39 9 90 to 99
4 40 to 49 P P0 to P9
5 50 to 59 E E0 to E9
5 Press [ESC] to end the process.
SCAN 10
10-3
121


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.