Examples on the configuration of Program Scan and
VFO Scan:
Configure the memory channels for specific band
segments such that the checkboxes for P1, P3 and
P5 are selected. Next, press F5 [SCAN]. Program
Scan starts and scanning is performed in the
frequency range registered for the respective
channels.
Configure the memory channels for specific band
segments such that all the checkboxes are
deselected and press F [SCAN]. Or press [VFO/
PRG] to switch the display to VFO SCAN. VFO Scan
is performed on the entire RX frequency band.
The checkbox will remain deselected for memory
channels that do not contain any operating data.
These checkboxes cannot be selected.
For more details on registering memory channels for
specific band segments, please refer to “Configuring
the Program Scan Frequency Range” on page 9-4.
Switching the Scan Speed
The time interval for switching the Program Scan (VFO Scan)
frequency can be configured in modes other than FM.
1 Press F3 [–] or F4 [+] while Program Scan (or VFO
Scan) is in progress.
The scan speed is shown below the frequency display.
.
The frequency switching interval changes as follows.
Scan Speed Display
Frequency Switching Interval
SCAN-SPD1 10 ms
SCAN-SPD2 30 ms
SCAN-SPD3 100 ms
SCAN-SPD4 150 ms
SCAN-SPD5 200 ms
SCAN-SPD6 250 ms
SCAN-SPD7 300 ms
SCAN-SPD8 350 ms
SCAN-SPD9 400 ms
Program Slow Scan
Program Slow Scan is a function that extends the frequency
switching interval (performs scan more slowly) using the
preconfigured frequency for performing Program Scan (frequency
point) and the frequencies before and after this point (segment).
Switching slowly between the specified frequency (frequency
point) and the corresponding segment allows the communication
status to be checked in detail.
To perform Program Slow Scan, register a frequency range to
a memory channel for specific band segments in advance.
Turning ON/OFF Program Slow Scan
To combine the use of Program Slow Scan while Program Scan is
running, set Program Slow Scan to ON in advance.
When scanned frequency falls in the segment for Program Slow
Scan during Program Scan, “SCAN-SLOW” is displayed on the
screen and the speed of frequency switching slows down.
Configure in Menu [4-02] Program Slow Scan
Setting Value Off/ On (default)
Configuring the Frequency Points for Program Slow
Scan
The frequency points for extending the frequency switching
interval during Program Slow Scan can be configured as follows.
Up to 5 frequency points can be configured for each memory
channel assigned to specific band segments (P0 to P9).
To configure the frequency points, register a band segment to
a memory channel for specific band segments in advance.
1 Press [M/V] to switch to the memory channel mode.
2 Press F7 [M.LIST] to display the Memory Channel
List screen.
.
3
Press F2 [ ] or F3 [ ], or turn the [MULTI/CH]
control to select a memory channel for specific
band segments.
4 Press F5 [SLW.SCN] to display the Program Slow
Scan screen.
.
10 SCAN
10-2
120


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info