Changing the Weighting
The electronic keyer allows the dot-dash weighting to be adjusted
automatically. Weighting is the ratio of the dash length to the dot
length.
2 weighting modes are available for selection: the “auto
weighting” mode changes the ratio automatically in tandem with
the keying speed, while the ratio is fixed in the “manual
weighting” mode and not affected by the keying speed.
When [2.5] (1:2.5) to [4.0] (1:4) is selected, the dot-dash weight
ratio is fixed regardless of the keying speed.
Configure in Menu [5-08] CW Keying Weight Ratio
Setting Value Automatic (default)/ 2.5 to 4.0 (0.1 step)
When this is configured to “Automatic”, the keying speed and
weight ratio settings are as follows.
Adjusting the Keying Speed Weight
4 to 24 1:2.8
25 to 44 1:3.0
45 to 60 1:3.2
Weight Ratio Reverse
When the weighting mode is configured to “Automatic”, increasing
the keying speed increases the weight ratio. Configuring the menu
below to ON decreases the weight ratio when the keying speed
increases.
Configure in Menu [5-09]
CW Keying Reversed
Weight Ratio
Setting Value Off (default)/ On
When weight reverse is enabled in the “Automatic” weighting
mode, the keying speed and weight ratio settings are as
follows.
Adjusting the Keying Speed Weight
4 to 24 1:3.2
25 to 44 1:3.0
45 to 60 1:2.8
CW Message Memory
This transceiver comes with memory channels that can store up
to 8 CW messages. In addition to paddle operation, a message
can be registered by entering a text using the USB keyboard or via
operating this transceiver.
CW message memory channels come in handy for messages
that are repeatedly transmitted as registering the messages in
advance allows them to be used repeatedly such as during
contest.
Switching the Method of Registering CW Messages
A method for registering messages can be selected from the
options below.
Configure in Menu [5-11] CW Message Entry
Setting Value Text String/ Paddle (default)
Text String: Registers messages using text strings.
Paddle: Registers messages via paddle operation.
Registering CW Messages via Text Input
Check to ensure that the CW message registration method in
Menu [5-11] is configured to “Text String”, followed by performing
the steps below to register a CW message. CW messages can be
stored in any of the channels from 1 to 8.
1 Press F2 [KEYER] to display the CW Message
screen (for text input).
.
When this transceiver is in a mode other than CW, F2
[KEYER] is not displayed in the key guide. Press
[CW/CW-R].
If the channel to register the CW message is not
displayed in the key guide, press F1 [MORE]. Doing so
switches the key guide.
2 Press and hold F2 [CH 1] to F5 [CH 4] or F2 [CH 5]
to F5 [CH 8] to select the channel to register the CW
message.
The CW message edit screen is displayed.
Pressing F7 [NEXT] each time switches between F2 [CH
1] to F5 [CH 4] and F2 [CH 5] to F5 [CH 8].
.
5 COMMUNICATING AIDS
5-14
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info