683161
59
Zoom out
Zoom in
Previous page
1/196
Next page
Switching the AGC Time Constant
1 Select a mode other than FM.
2 Press [AGC] to select an AGC time constant.
Pressing [AGC] each time switches the selection in the
following sequence: “AGC-F” → “AGC-M” → “AGC-S”.
.
Adjusting the AGC Time Constant Preset Value
1 Press and hold [AGC] to display the AGC
configuration screen.
.
2 Press F3 [AGC] or [AGC] to select “FAST”, “MID” or
“SLOW”.
3 Press F4 [–]/ F5 [+] or turn the [MULTI/CH] control
to change the AGC time constant.
Setting Value 1 to 20
The AGC time constant is fastest when it is configured to “1”,
and slowest when configured to “20”.
The default AGC time constant values in the respective
operation modes are as follows.
Mode
FAST MID SLOW
SSB 9 12 14
SSB-DATA 9 12 14
CW 9 12 14
FSK 7 11 14
PSK 7 11 14
AM 9 13 16
AM-DATA 9 13 16
4 Press and hold [AGC] or press [ESC] to end the
process.
AGC OFF
Turns off AGC according to the status of the signals received. RF
gain is fixed when AGC is set to OFF, which makes it easier to hear
weak signals in some cases.
If AGC is turned OFF while the S meter is deflecting due
to the signal, sound may be output to the speaker or
headphones at an unexpectedly loud volume.
Turn the [RF] control to turn down the RF gain level in advance.
After turning off AGC, adjust RF gain by turning the [RF] control
until the signal can be heard clearly.
To turn off AGC, perform the steps below.
1 Press and hold [AGC] to display the AGC
configuration screen.
2 Press and hold F6 [(OFF)] to configure AGC to OFF.
<< >> lights up and the preset value display area is
grayed out.
3 Press and hold [AGC] or press [ESC] to end the
process.
AGC Quick Recovery
This function performs recovery from the suppression that occurs
when the RX signal contains pulse noise.
1 Press and hold [AGC] to display the AGC
configuration screen.
2 Press F2 [PULSE] to display the AGC Quick
Recovery configuration screen.
.
3 Press F3 [ON/OFF] to set the function to “On”.
4 Press F4 [–]/ F5 [+] or turn the [MULTI/CH] control
to change the threshold level.
Configuring to a larger value activates this function when signal
level difference between the RX signal and pulse noise is small.
Setting Value
1 to 5 (default) to 10
This function may not be effective for pulse noise
occurring in short time interval.
Configuring to a value with a high threshold level may
cause the transceiver to malfunction and distort the RX
audio depending on the condition of the RX signal.
5 Press and hold [AGC] or press [ESC] to end the
process.
COMMUNICATING AIDS 5
5-3
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info