33
COMMUNICATING AIDS 7
CUSTOMIZING TRANSMISSION SIGNAL
CHARACTERISTICS
The quality of your transmission signal is important,
regardless of which on-air activity you pursue.
However, it is easy to be casual and overlook this fact
since you don’t listen to your own signal.
The following sub-sections provide information that will
help you tailor your transmission signal.
TX Filter Bandwidth (SSB/ AM)
Use Menu No. 31 to select one of the following TX
low-cut fi lters: 10, 100, 200, 300 (default), 400, or
500 Hz.
Use Menu No. 32 to select one of the following TX
high-cut fi lters: 2500, 2600, 2700 (default), 2800,
2900, or 3000 Hz.
TX Filter Bandwidth (SSB-DATA)
Use Menu No. 33 to select one of the following TX
low-cut fi lters: 10, 100, 200, 300 (default), 400, or
500 Hz.
Use Menu No. 34 to select one of the following TX
high-cut fi lters: 2500, 2600, 2700 (default), 2800,
2900, or 3000 Hz.
TX Equalizer (SSB/ SSB-DATA / FM/ FM-DATA/ AM/
AM-DATA)
Use Menu No. 36 to change the transmission
frequency characteristics of your signal. You can
select from 1 of 6 different transmission profi les
including the default fl at response. Selecting any
of the following items from the Menu causes
to appear on the display.
• Off (oFF):
The fl at frequency response (default).
High boost 1 (Hb1)/ High boost 2 (Hb2):
Emphasizes higher audio frequencies; effective
for a bassi voice. High boost 2 does not reduce
the low frequency as much as High boost 1.
Formant pass (FP):
Improves clarity by suppressing audio
frequencies outside the normal voice frequency
range.
Bass boost 1 (bb1)/ Bass boost 2 (bb2):
Emphasizes lower audio frequencies;
effective for a voice with more high frequency
components. Bass boost 2 emphasizes more
low frequency response.
• Conventional (c):
Emphasizes by 3 dB frequencies at 600 Hz and
higher.
• User (U):
Reserved for the optional ARCP software.
Off (oFF) is programmed at the factory as a
default.
Frequency Response Curves
0.1 1.0
2.0
Amplitude
Audio frequency (kHz)
oFF
Hb2
HP
bb1
c
Note:
When using the ARCP-590G, you can temporarily change
each preset value.
The TX Equalizer properties are stored in each of the
following modes.
SSB/ SSB-DATA/ CW/ FSK / FM/FM-DATA/ AM/ AM–DATA
TRANSMIT INHIBIT
Transmit Inhibit prevents the transceiver from being
placed in transmission mode. No signal can be
transmitted when this function is ON, even if Mic [PTT]
is pressed.
TX Inhibit OFF: Transmission is allowed.
TX Inhibit ON: Transmission is not allowed.
Switch this function ON or OFF via Menu No. 66.
The default is OFF.
BUSY LOCKOUT
Busy Lockout prevents the transceiver from being
placed in transmit mode if the current operating
frequency is busy; in other words, if the squelch is
open, you cannot transmit.
Busy Lockout OFF: Transmission is allowed.
Busy Lockout ON: Transmission is not allowed.
Switch this function ON or OFF via Menu No. 81.
The default is OFF.
CHANGING FREQUENCY WHILE TRANSMITTING
Moving your frequency while transmitting is usually an
unwise practice due to the risk of interfering with other
stations. However, if necessary, by using the Tuning
control you can change the operating frequency while
transmitting. You also can change the XIT offset
frequency while in transmission mode.
While transmitting, if you select a frequency outside
the transmission frequency range, the transceiver is
automatically forced to return to reception mode.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-590SG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-590SG in the language / languages: English as an attachment in your email.

The manual is 4,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-590SG

Kenwood TS-590SG User Manual - German - 96 pages

Kenwood TS-590SG User Manual - Dutch - 96 pages

Kenwood TS-590SG User Manual - French - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info