A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
Print welds
On the Print Weld Files screen you can print to the built‐in
paper tape printer and/or an internal memory location.
Printing to the printer provides an immediate hard copy
of the weld program. You can print weld programs to
memory one or more times over a period of time and then
download them to a memory stick for storage or transfer
them to other electronic media. The contents of memory
will be deleted.
1. On the Maintenance Menu, select Print Welds.
2. Select Weld To Print.
3. Using the control knob, enter the weld number to
print.
4. Select Print or Store File.
5. Use the control knob to select: Memory, Printer, or
Both.
6. Select Short Form (parameters only) or Long Form
(parameters, as well as all procedure information
and notes).
7. To save the settings that have been changed on the
Maintenance / Print Weld Files screen, press Save.
Memory Internal memory
Print Transfer les for printing to integrated printer
or transfer to memory stick for printing using
a PC.
Automatic
Printout
If set to Yes, the printout automatically occurs
following each weld.
Transferring print les to memory stick
You can use a memory stick to transfer or move les to
a standard PC equipped with a printer for later printout.
1. Select the weld number to transfer and use the
control knob to select Print to Memory, Print, or
Both.
2. Press Print. A screen will state that the weld has
been successfully saved to memory.
3. Save one or more welds to print later. (The memory
stick does not have to be installed at this time.)
To transfer a weld program from internal memory to a
memory stick:
1. Place the stick in the USB port in the front panel.
2. The stick will require approximately 1 minute to
initialize, at which time the LCD on the side of the
key will slowly pulse.
3. When the stick is ready, the LCD blinks rapidly 5
times.
4. If no stick is installed or it has not yet nished
initializing, an error message displays.
5. Press Dnload to download all stored print les to
the stick.
Dnload will delete these programs from memory.
You can open the print les saved on a memory stick in any
text editor, such as Microsoft® Word, Microsoft® Notepad,
or Microsoft® Excel.
In case you see an error message, return to Main
Menu and re-enter the print screen. “Error” will change to
“Dnload”. If a memory stick is installed and initialized prior
to entering the print screen, this step is not required.
Printout (300 and 150 series weld heads only)
At weld completion, the 300-series provides an immediate
unambiguous report that indicates whether a weld was
made. It is not a complex data‐logging program, and
it does not require interpretation of chart/graphical
printouts of the entire weld.
The following information is printed out:
Weld ID number
Date
Time
Operator’s name
Welding parameters from each layer
Printable information can also be stored on a memory
stick via the USB connector on the remote control.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 TIG Orbital System 300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 TIG Orbital System 300 in the language / languages: English as an attachment in your email.

The manual is 4,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info