686369
25
Zoom out
Zoom in
Previous page
1/66
Next page
25
A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
4. ACCESSING THE WEB USER
INTERFACE
4.1 Configuring the network settings
The web user interface starts up automatically on power-
up. However, before one can access the Web UI from the
computer connected to the web user interface server, the
network settings must be properly congured from the
setup panel.
Go to the Main menu > Robot > Network settings, and
congure the DHCP enabled, IP address, Subnet mask,
and Gateway parameters to match your networking
environment.
DHCP
If you have a DHCP server in your network and you want to
enable a DHCP client function in the Web UI, change the
DHCP enabled parameter’s value to ON. The IP address,
subnet mask, and gateway information will come from
the DHCP server, and you don’t need to congure these
parameters. Switching this parameter’s value to OFF lets
you specify the IP settings manually.
When the DHCP client is switched on, it takes some
time for the client to establish a connection to the DHCP
server and retrieve the address information. Usually the
retrieval time is no longer than 60 seconds. During that
time, the old values are displayed for the IP address, subnet
mask, and gateway.
IP address
Specify an IP address for the web user interface server
(DHCP disabled) – for example, 10.0.0.20 – or display the
address given by the DHCP server (DHCP enabled).
Subnet mask
Specify a subnet mask for the web user interface server
(DHCP disabled) – for example, 255.255.255.0 – or display
the mask given by the DHCP server (DHCP enabled).
Gateway
The web user interface does not use a gateway address.
You can leave this parameter as it is (DHCP disabled) or
display the address supplied by the DHCP server (DHCP
enabled).
Congure your computers network settings accordingly.
Ensure that your computer has an IP address dierent
from that of the web user interface – for example,
10.0.0.21. Other settings must match each other.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 MIG Welder 350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 MIG Welder 350 in the language / languages: English as an attachment in your email.

The manual is 5,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info