The only indication that the membranes might benefit from cleaning is a substantial reduction in
the quantity of product freshwater output, all other factors being normal (e.g., battery voltage,
salinity, seawater temperature). The best way to detect such a problem is by keeping an
accurate log of product freshwater output at known battery voltages. Such a practice is highly
recommended.
If you have determined that your membranes need cleaning and you know the type of deposits
(mineral or organic), use the appropriate cleaner. If you do not know the nature of the deposits,
try cleaning first with the
Alkaline Cleaner and check for improvement in product
freshwater output. If output remains poor, repeat the cleaning process using the
Acid
Cleaner
. Never mix the two types of cleaners! Always flush well with clean water between
processes if performing both alkaline and acid cleaning. The following directions apply for both
types of membrane cleaners:
1. Turn the clean/run valve lever on the pump to its “clean” position (see Figure 8).
2. Discard any dirty seawater in the prefilter assembly. Clean the housing and install a clean
element
3. Fill a clean plastic container or bucket with one gallon (approximately 4 liters) of clean
water. Freshwater is preferable, but clean seawater may be used if freshwater is not
available. (Caution: Never use chlorinated freshwater. This may damage the
membrane.)
4. Mix four spoonful (approximately 40 grams) of either Acid Cleaner or Alkaline Cleaner
(not both!) with the water in the container and stir until the cleaner is completely
dissolved. The water should be warm, but not over 120° F (49° C).
5. Turn the lever on the prefilter 3-way valve to the alternate intake position. Run the 1/4"
alternate intake hose with the strainer attached into the container of cleaning solution.
6. Disconnect the reject brine water hose from its drain (or use a separate length of hose) to
route the reject brine water back into the container of cleaning solution during the
following procedure.
7. Turn on the watermaker. Discard any solution coming from the reject brine hose for about
30 seconds. Then run the reject brine water hose back into the container of cleaning
solution to allow recirculation of the cleaner.
8. Continue to run the watermaker for about 15 minutes, to assure that the cleaning solution
is well circulated through the pump and membrane housing.
9. Turn off the watermaker and allow the membranes to soak in the cleaning solution for 5
to 10 hours, or overnight. For severe fouling, repeat Steps 8 and 9 of this procedure.
10. When the soaking is finished, remove the reject brine hose from the cleaning solution
container and run the watermaker again. Discard the first pulses of the reject brine water.
When the reject brine flow becomes cleaner, return the reject brine hose to the cleaning
solution container for recirculation.
11. Continue to run the watermaker and recirculate the cleaning solution for another 30 to 60
minutes
12. When cleaning is complete, turn off the watermaker. Reconnect the reject brine hose to
its normal drain location.
13. Remove the alternate intake hose and strainer from the cleaning solution and place them
into a container of clean, warm (non-chlorinated) freshwater. If freshwater is not
available, clean seawater may be used if its temperature is above 68° F (20° C).
14. Turn on the watermaker and flush warm water through the system for 5 minutes.
If the watermaker will be stored for more than a week (three days in warm climates), it should
now be treated with the membrane preservative solution.
14
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Katadyn PowerSurvivor 80E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Katadyn PowerSurvivor 80E in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Katadyn PowerSurvivor 80E

Katadyn PowerSurvivor 80E User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info