2. Clamp the pump between your feet and
take hold of the carrying handle.
3. Unlatch the filter basket by turning the
handle clockwise.
4. Move the filter basket into the required
position.
5. Lock the filter basket in place by turning
the handle anticlockwise.
Automatic mode
In automatic mode, the float switch controls
the pumping process automatically.
The pump switches on as soon as the float
switch reaches the switch-on height
caused by the rising fluid level.
The pump switches off as soon as the float
switch reaches the switch-off height caused
by the sinking fluid level.
The float switch must be able to move free-
ly.
Note
The switching heights vary depending on:
Position of the float switch
Cable length between the float switch
and lock.
The cable length must be at least
2.5 cm. We would recommend retaining
the set cable length.
For information on the switching heights,
see chapter Technical data.
1. Set the float switch using the height ad-
justment, and the cable length between
the float switch and the lock.
Note
When the pump is operated unattended,
always set the float switch to the upper-
most position in order to ensure that the
pump can switch off reliably.
Illustration F
When the float switch is set to the lower-
most position, set the cable length be-
tween the float switch and the lock to
2.5 cm, see marking on the cable.
Illustration G
2. Move the filter basket into the "waste
water and clear water delivery" position.
3. Plug the mains plug into the socket.
Manual operation
In manual operation, the pump stays
switched on.
The residual fluid height (see chapter
Technical data) can only be reached in
manual operation.
ATTENTION
Damaging the pump due to dry running
Increased wear and tear
Do not leave the pump unattended in man-
ual operation.
Switch off the pump for dry running.
1. Fasten the float switch in the lock, with
the nose pointing upwards.
Illustration H
2. Move the filter basket into the required
position, depending on the fluid level (for
the minimum fluid height and residual
fluid height, see chapter Technical da-
ta).
3. Plug the mains plug into the socket.
Optimising the flow rate
The flow rate is further increased:
The lower the delivery height is
The greater the diameter of the hose
used is
The shorter the hose used is
The smaller the pressure loss caused by
the connected up accessories
Ending operation
1. Remove any dirt from the device.
Pump clear water.
Rinse out the pump.
2. Press the button for Quick-Connect and
remove the pipe union.
Illustration I
The hose is removed.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher SP 5 Dual at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher SP 5 Dual in the language / languages: All languages as an attachment in your email.

The manual is 3,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info