key for 2 seconds and press the fkey until the display shows the message “M3 Adjust
vent 1”.
Press the key and set the desired ventilation speed using the keys and .
To con! rm your choice, press the key.
SCREW LOADING (only if the stove is completely without pellets)
To load the screw, enter the MENU by pressing the key
for 2 seconds; then press the key until the message “M5 Screw
loading” appears on the display.
Press the key
to con! rm, and then the key to activate the function.
This operation must only be carried out when the stove is off and completely cold.
Note: during this phase, the smoke extractor fan will remain on.
STAND-BY FUNCTION
In this mode, the stove will go off when the temperature of the environment is 0.5°C higher than that requested, after a set time of
10 minutes (which can be changed by the TAC during installation).
The message “GO STBY” will appear on the display, indicating the minutes remaining before switch-off.
This function is available in both ‘AUTOMATIC’ or ‘MANUAL’ mode and in the case of an external thermostat.
If the environmental temperature falls to 2°C below the set threshold, the stove will start up again (setting modi! able by the TAC
during installation).
To activate the function, press the key for about 3 seconds; the message “M1 set clock” will appear on the display; press the
key
until the message “M6 stand by” appears on the display, then con! rm by pressing the key .
Press the key to select “ON”, then con! rm by pressing the key .
To quit the menu “M6 stand by”, press the key for about 6 seconds.
SETTING THE DATE AND TIME
Press the key
for about 2 second; the message “M1 set clock” will appear on the display; then con! rm by pressing the key .
The following data will appear in sequence: Day of the week, hour, minutes, day, month, year; these can be changed by pressing
the key
or the key . To con! rm, press the key .
To quit the menu “M1 set clock”, press the key for about 6 seconds.
EXTERNAL THERMOSTAT
This must be connected by the blue wire (optional code 640560) to the serial port positioned on the back of the stove; it must have
a clean, normally open contact (e.g. in the case of an environmental thermostat):
- Open contact = Environmental temperature reached
- Closed contact = Environmental temperature not reached
To select ‘E-T’ (external thermostat) mode, press the key
(the LED will light up). Pressing the key will lower the tem-
perature until the message ‘E-T’ (external thermostat) appears on the display (below 6°).
Note: When the stove is off, the external thermostat cannot switch the stove on or off.
If you want to switch the stove on or off outside the set time or outside the ‘E-T’ (external thermostat) setting, you must always
do so using the key
.