technical specifications
9
Type number AC127W
Voltage 220-240Volt ~50Hz
Connected load 1600 Watts
Cooling capacity* 12,000 Btu/h (3.5 kW)
EE Class* A
EER* 2.6
Power consumption kW 1.4
Power consumption Standby W 0.5
Current consumption nom. A 5.9
Air displacement max. m3/h 465
Dehumidification max. ** L/24h 69.6
Suitable for m3105
Refrigerant / GWP type/gr R-290/3/240 g.
thermostat range °C 16 - 30
Fan speeds 3
Max. noise level dB(A) 63 dB
Dimensions (hxwxd) 825 x 496 x 425 mm
Nett weight 36.7 kg
Protection class IPX0
Remote control yes
problems and solutions
8
First check the following before submitting the air conditioner for repair.
Problem Possible cause Solution
The appliance does not switch on when pressing
the on/off key.
The indicator light on the water tank flashes and the water
tank is full.
Empty the water tank.
The room temperature is lower than the set temperature. Set the temperature once more.
The appliance does not cool sufficiently.
Not all doors and windows are closed. Make sure that all doors and windows are closed.
There are heat sources that are active in the room. Remove the heat sources or switch them off if possible.
The temperature is set too high. Set the temperature once more.
The air inlet is blocked. Clean the air inlet grille.
The appliance makes a lot of noise.
The surface on which the appliance is placed is not level
of flat enough.
Place the appliance on a flat surface, level if possible.
The noise is caused by the flowing refrigerant liquid within
the air conditioner.
This is normal.
The appliance does not respond to the remote control The appliance has been switched on via the control panel
on the appliance itself.
The remote control has not been activated.
Press the on/off button on the remote control to activate it.
The appliance does not switch on for a period of 3 minutes
after it has been switched on.
The internal safety system of the compressor prevents
the appliance from being switched on until 3 minutes have
passed since it was switched off.
This delay is normal and the appliance will function
normally after the 3 minutes have passed
Error code P1 The water tank is full. Empty the water tank.
For a maximum performance of the appliance, observe the following recommendations:
Close the windows and doors of the rooms to be cooled. If you want to leave the appliance in a room, we recommend leaving the door slightly open ( 1 cm ) so that a good ventilation
can be provided.
Close curtains and/or blinds to keep out the sun, so that the appliance does not have to cool as much and consumes less energy.
Do not place anything on top of the appliance.
Do not cover the air inlets and outlets. Make sure all grilles are uncovered.
Ensure there are no heat sources in the room.
Do not use the appliance in very humid rooms, such as bathrooms and laundry rooms.
Never use the appliance outdoors.
Make sure the appliance is placed on a flat, stable surface.
tips for efficient use
7
English 29
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventum AC127W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventum AC127W in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info