790073
28
Zoom out
Zoom in
Previous page
1/64
Next page
LOCK BUTTON
To prevent the settings of the remote control from being changed, you can lock them with the lock.
Hold down both keys [ ] and [ ] at the same time for 5 seconds in order to activate the lock. A lock appears in the display on the remote control .
It is no longer possible to control the appliance with the remote control.
Press the lock button once more to deactivate the lock. The lock disappears and the appliance can be controlled again by means of the remote control.
DISPLAY LIGHT
If the display light on the appliance bothers you, you can switch it off by pressing the [ ] key.
Press the key once more to reactivate the display light.
AUTOMATIC RESTART AFTER POWER INTERRUPTION
After a power interruption, the appliance automatically restarts in accordance with the latest settings, once the power supply has been restored. Dit takes a few minutes.
CHANGING THE TEMPERATURE UNIT CELSIUS / FAHRENHEIT
Simultaneously hold down the + and - keys for 3 seconds to change the display of the temperature unit from Celsius [ °C ] to Fahrenheit [ F ].
SAFETY
In order to protect the appliance, it has a safety by means of which it is not possible to switch the appliance on again within 3 minutes after switching it off.
When you have switched off the appliance, you must wait 3 minutes before switching the appliance on again.
When the air conditioner is not used for a longer period of time, remove the cover cap from the drain opening at the bottom of the appliance and place an empty cup under the outlet.
All the water will flow out of the tank.
The water tank is equipped with an alarm sensor. When the water reaches a certain level in the water tank, the appliance beeps 8 times and P1 appears
inthe display. The cooling process is switched off automatically. It is possible that the appliance continues with air circulation.
Manual discharge - when using the appliance in a room with high air humidity.
1. Remove the plug from the socket.
2. Place a low receptacle under the lower outlet for condensation water discharge. See the drawing.
3. Remove the screw cap.
4. The water flows out of the drain into the receptacle.
5. Place back the screw cap when no more water is flowing out.
6. Switch the appliance on again.
Continuous discharge - recommended when using the dehumidification position.
For continuous discharge of condensation water we recommend following the method described on page 13 at the section DE-HUMIDIFICATION.
draining condensation water
5
screw cap
outlet
cleaning and maintenance
6
Before cleaning the air conditioner, switch off the appliance by means of the ON/OFF key, wait a few minutes and remove the plug from the socket.
Cleaning the exterior
Clean the exterior of the appliance with a slightly damp cloth and then wipe it with a dry cloth. If necessary, you can clean the exterior of the appliance
bymeans of a mild washing-up liquid.
Never wash the appliance with water. This can be dangerous.
Do not use petrol, alcohol or similar solvents to clean the appliance.
Never spray with insect sprays or similar agents.
Do not use aggressive or abrasive cleaning agents for cleaning the appliance.
Never submerge the appliance, cord or plug in water or any other liquid.
The air filter
In order to allow the appliance to function as well as possible, we recommend cleaning the air filter regularly. The air filter could get clogged with dust
anddirt.
In order to remind you to clean the air filter, you can activate the warning light for the filter.
Press the sleep mode key [ sleep / ] for 3 seconds.
When the appliance has been functioning for 250 hours, the warning light filter lights up to indicate that you should clean the filter. Clean the filter
according to the instructions and reset the function by pressing the key [ sleep / ] for 3 seconds again.
Cleaning the air filter
Switch off the appliance and remove the plug from the socket.
Remove the air filter as shown in the drawings.
Use a vacuum cleaner to remove all the dust from the air filter.
If the air filter is very dirty, you can clean it with lukewarm water.
Submerge the air filter in lukewarm water (max. 40°C) containing a soft cleaning agent. Rinse the air filter a few times and allow it to dry in the air.
Donotplace the air filter in the sun or on the heating to dry it.
Place back the air filter. Check that it is fully dry, before using the appliance again.
Cleaning the air inlets
In order to allow the appliance to function as well as possible, you can clean the air inlets by means of a vacuum cleaner with a soft brush nozzle.
Start or end of the season
At the start of the season, check that the cord and plug are undamaged. Observe the installation instructions when placing the appliance.
At the end of the season, make sure there is no condensation water left in the appliance. Drain the water according to the instructions in section
DRAINING CONDENSATION WATER and switch on the appliance for 12 hours in the air circulation mode to make sure that the appliance dries internally
and no mould is created.
Ensure the air filter is clean before storing the appliance and remove the batteries from the remote control.
28 English
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventum AC127W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventum AC127W in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info