Follow these instructions when using the appliance for the first time: Carefully unpack the air conditioner and all accessories and remove all packaging material and any promotional
stickers.
Keep the packaging (plastic bags and cardboard) out of reach of children.
After unpacking the appliance, carefully check it for external damage that may have occurred during transport.
Place the appliance on a sturdy, flat surface and make sure there is enough space all around for sufficient ventilation. Check that all mentioned accessories have been supplied.
Clean the air conditioner with a slightly damp cloth.
Prior to connecting the appliance, check that:
the connection voltage corresponds with what is stated on the information plate;
the socket and cord are suitable for the appliance;
the plug of the cord fits in the socket;
the appliance is placed on a stable and flat surface.
PLACEMENT OF THE AIR CONDITIONER
The appliance must be placed on a sturdy and flat surface with sufficient room all around.
Do not block the air outlet and ensure a free space of minimum 25 cm around the appliance.
After placing the appliance in a straight position allow it to stand for at least 2 hours before inserting the plug in the socket.
For the benefit of easy movement, the appliance has been provided with castors.
Carefully roll the appliance over the floor. Make sure the floor is flant and try not to drive over objects.
REMARK: Optimum operation of the appliance depends on the length of the discharge hose and the number of bends.
Trytolimit both. The supplied flexible discharge hose has a maximum length of approx. 150 cm and
corresponds with the capacity of the appliance. The use of any other hoses or extensions could cause
failures in the appliance. The air should be able to flow without hindrance, or else this could lead to
overheating of the appliance or condensation of water in the air discharge hose. Therefore make sure there
are no kinks or sharp bends in the discharge hose. For an optimum result, the discharge hose should be kept
shorter than 1 metre during use of the appliance.
prior to first use
3
25cm
25cm
50cm
25cm
INSTALLATION OF THE WINDOW SEAL SET
The flexible window seal set is suitable for many windows. Such as: tilt and turn windows, windows turning to the outside and inside. It ensures that you are able to hang the discharge
hose to the outside, without hot air flowing into the room again or having problems with insects.
For windows turning to the outside, we recommend taping all four sides (a+b+c+d) around the window and for windows turning to the inside only three sides (a+b+c).
Attach the supplied double-sided tape on the window frame and the window in accordance with one of the drawings below that is similar to your situation.
Then attach the cloth to the tape that you attached in the openings.
1. Attach the supplied double-sided tape on the window frame.
2. Then attach double-sided tape on the window.
3. Cut away excess tape.
4. Make sure the tapes on the corners properly overlap to achieve proper sealing.
5. Attach the cloth to the tape attached to the window frame and window.
6. Make sure the cloth is neatly attached to the tape on both sides.
7. Zip open the cloth.
8. Insert the discharge hose through the opening and zip the cloth closed to achieve proper sealing.
Fig. 1 Fig. 2 Fig. 3 Fig. 4
Fig. 5 Fig. 6 Fig. 7 Fig. 8
WALL INSTALLATION
Drill a 125 diameter hole in the wall, for the wall outlet with valve.
Fasten the wall outlet with the provided screws and plugs.
Attach the end of the discharge hose with the wall outlet connector to the wall outlet.
Close the valve of the wall outlet when the appliance is not being used.
plugs
wall outlet
with valve
max. 140 cm.
min. 80 cm.
English 25
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventum AC127W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventum AC127W in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info