a) Familiarize yourself with the equipment and its operation.
b) Disconnect the electrical connection between the system nd the power supply.
c) Prior to starting the work, check that the following items have been met:
All required mechanical provisions are present, e.g. to handle the refrigerant cylinders;
All personal protective equipment is present and is used correctly;
There is always a competent person present who supervises the draining process;
All draining equipment and storage cylinders comply with the applicable standards.
d) Preferably pump empty the cooling system, if this is possible.
e) If pumping empty is not possible, use a suitable distributor to remove as much refrigerant as possible from the different
sections of the system.
f) Place the cylinder on the weighing scale before draining starts.
g) Start the draining system and work in accordance with the manufacturer's instructions.
h) Never fill cylinders by more than is permitted. (Maximum 80% liquid volume).
i) Never exceed the maximum operating pressure of the cylinder, not even briefly.
j) When the cylinders are filled correctly and the process has been completed, immediately remove all cylinders and
equipment from the location and close all valves of the equipment.
k) Never fill drained refrigerant in another cooling system, before cleaning and checking it.
15. Marks (Appendix DD.12)
Apply markings on the equipment stating that it has been decommissioned and that the refrigerant has been removed.
Writethe date on the marking, as well as your name. Apply markings on the equipment indicating that the equipment contains
combustible refrigerant.
16. Draining (Appendix DD.13)
When removing refrigerant from a system, for maintenance or decommissioning, it is recommended to remove all refrigerants
to a safe location. When draining refrigerant, only use cylinders that are suitable for storing refrigerant. Ensure there are
sufficient cylinders available to store the entire volume of the cooling system. Only use cylinders that are suitable for storing
the refrigerant to be drained and apply markings indicating which refrigerant they contain (i.e. use special storage cylinders).
The cylinders must be complete, including properly functioning overpressure valves and valves. Pump empty storage cylinders
empty and cool them, if possible, before gas is stored in them.
The draining system must be in a good condition and have a manual describing the equipment used, and must be suitable
for collecting combustible refrigerants. In addition, a calibrated weighing scale should be available that is working correctly.
Allhoses should be provided with coupling that work correctly and are free from leaks. Prior to using the draining system,
checkthat it is in a good conditions, well maintained and that all accompanying electrical components are sufficiently guarded
to prevent ignition in the event of a refrigerant leak. In case of doubt, consult the manufacturer.
Hand in the collected refrigerant in the correct storage cylinder at the refrigerant supplier and ask for a receipt for the submitted
waste materials. Do not mix refrigerants in the draining system and certainly not in the cylinders.
If compressors or compressor oils must be removed, first empty the appliance to a level at which no combustible refrigerant
remains in the lubricant. Emptying should take place before the compressor is sent back to the supplier. The compressor body
may only be heated electrically in order to accelerate the process (not with an open flame). When oil must be removed from
asystem, do this in a safe way.
English 23
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventum AC127W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventum AC127W in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info