771744
10
Zoom out
Zoom in
Previous page
1/136
Next page
Page 10
Features
Default Setting
When the air conditioner restarts after a power
failure, it will default to the factory settings
(AUTO mode, AUTO fan, 24°C (76°F)). This
may cause inconsistencies on the remote
control and unit panel. Use your remote
control to update the status.
Auto-Restart
In case of power failure, the system will
immediately stop. To restart the unit, press the
ON/OFF button on the remote control. If the
system has an auto restart function, the unit will
restart using the same settings.
Energy Saving Tips
DO NOT
set the unit to excessive temperature levels.
While cooling, close the curtains to avoid direct sunlight.
Doors and windows should be kept closed to keep cool or warm air in the room.
DO NOT
place objects near the air inlet and outlet of the unit.
Set a timer and use the built-in SLEEP/ECONOMY mode if applicable.
If you don’t plan to use the unit for a long time, remove the batteries from the remote contr
ol.
Clean the air lter every two weeks.
Adjust louvers properly and avoid direct airow.
Louver Angle Memory Function
Some models are designed with a louver angle
memory function. When the unit restarts after a
power failure, the angle of the horizontal louvers
will automatically return to the previous position.
The angle of the horizontal louver should not be
set too small as condensation may form and drip
into the machine. To reset the louver, press the
manual button, which will reset the horizontal
louver settings.
Closing curtains during heating also
helps keep the heat in
Doors and windows should be kept
closed
Refrigerant Leak Detection System
In the event of a refrigerant leak, the LCD screen
will display “EC” and the LED indicator light will
ash.
For a detailed explanation of each function,
refer to the Remote Control Manual.
Page 11
Manual Operations 3
The display panel on the indoor unit can be used to operate the unit in cases when the remote
control has been misplaced or is out of batteries.
Room Temp/Set
Temp/Set Timer
display
Fan speed
operation
display
Auto operation
Cooling operation
Dry operation
Heating operation
Fan operation
Vertical airow
Horizontal airow
Avoid direct
Lock operation
1MODE button: Press this button to select the appropriate operating mode. Each time the button
is pressed, the operation mode is shifted in the direction of the arrow:
Operation buttons
Mode indicators light up to signal the following mode settings.
AUTO COOL DRY HEAT(for cooling & heating models only) FAN ONLY
Auto: Automatically chooses the operation mode by sensing the difference between the actual
ambient room temperature and the set temperature on the remote controller. The fan speed is
automatically controlled.
Cool: Enables you to enjoy the cooling effect at you preferred setting temperature (Temperature
range:17°C~30°C).
Dry: Enables you to set the desired temperature at medium fan speed which provides you with
the dehumidied surroundings (Temperature range: 17°C~30°C). In Dry mode, you cannot select
Fan speed and Sleep mode.
Heat: Permits heating operation (For cooling & heating models only, temperature setting range:
17°C~30°C).
Fan only: Permits fan operation without cooling or heating. In this case, however, the setting
temperature is not displayed and you cannot adjust the set temperature.
4
6
5
1
2
3
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V5MFI32-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V5MFI32-60 in the language / languages: English as an attachment in your email.

The manual is 20.26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor V5MFI32-60

Inventor V5MFI32-60 Additional guide - English - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info