2Avoid button:
1. In any mode of boot, press the button to turn on the function.
2. Press “ ” , “ ”, “ ” close this function.
3Power button: Operation starts when this button is pressed and stops when you press the
button again.
4Fan button: This button is used to select the desired fan speed. Each time you push the
button, the fan speed is shifted in the following sequence:
5Swing button:
6button
LOW MED HIGH AUTO
Fan speed display:
Select LOW fan speed and zones 1~2 will illuminate.
Select MED fan speed and zones 1~4 will illuminate.
Select HIGH fan speed and zones 1~6 will illuminate.
Select AUTO fan speed and zones 1~7 and “AU” will illuminate .
Note: When using the remote control to choose strong wind, wind speed 1~7 will illuminate.
1. This button is used to set the horizontal and vertical airow.
2.Each time the airow direction button is pressed, the settings change as follows: Set
vertical airow Cancel vertical airow Set horizontal airow Cancel horizontal airow
Set simultaneous vertical and horizontal airow Cancel simultaneous vertical and
horizontal airow Set horizontal airow.
WARNING: Manually moving the horizontal and vertical airow direction louvers could damage
the air conditioner.
1.Under the Test Running mode, press " " " " to be able to check view indoor, outdoor, fault code .
In other states,press the " "and" " to adjust the temperature within a range of 17°C~30°C
To cut to 17 °C again when press downward adjustments set temperature no longer change;
To rise to press adjusted upward again when 30 °C set temperature no longer change.
When setting the temperature, the key cannot adjust the temperature quickly, it can only be
achieved by pressing up and down.
3.
When a failure occurs, E0, E1, E3, E4, E5, Eb, EC, E10, F1, F2, F5, P10, P11, P12, P15, P13, P14, P9.
(for Fixed-speed Type only)
2.
1 2 4 6 7
Page 13
LOCK FEATURE: The lock feature is activated by pressing down and holding the fan speed and
swing buttons simultaneously for a period of one second.
NOTE:
This feature is available both when the unit is turned on or off. The rst time these buttons are
pressed, the unit locks and all other buttons on the unit are disabled (apart from the unlock button).
Please note that the remote control can still be used when the unit is locked. Press the button of the
panel and the lock icon will blink for 5 seconds at 1HZ/SWhen these buttons are pressed again the
unit is unlocked.
Trial operation conditions showed that temperature of T1, if the temperature is less than -15ºC
or - 19ºC, display temperature of -15ºC or - 19ºC.
Trial operation conditions showed that T4 temperature, if the temperature is less than - 19ºC,
show the temperature for - 19ºC.
Trial operation condition, T1, T4 showed highest temperature is 50ºC or 70ºC.
Under test mode, sensor fault can be detected.
The mode key, the wind speed key and the auxiliary function key are not valid, and all other keys are
valid (including the key). Press up and down to select the display room (T1), outdoor (outdoor
temperature), and protection code, and show "nA" when there is no failure or protection.
Commissioning function: Press " “ and ” " for one second to open the test run, the key is
valid in any mode when it is turned on. On the rst time, press this button to enter the test run
state.Run the test run for 30 minutes, press this button again, turn off, and exit the test run condition.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V5MFI32-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V5MFI32-60 in the language / languages: English as an attachment in your email.

The manual is 20.26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor V5MFI32-60

Inventor V5MFI32-60 Additional guide - English - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info