CAUTION
CAUTION
CAUTION
This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
This symbol shows that information is available such as the operating
manual or installation manual.
This symbol shows that this appliance uses a ammable refrigerant. If the
refrigerant is leaked and exposed to an external ignition source, there is a
risk of re.
This symbol shows that the operation manual should be read carefully.
WARNING
CAUTION
Explanation of symbols displayed on the indoor unit or outdoor unia
(applicable to the unit adopts R32/R290 Refrigerant only):
Note about Fluorinated Gasses
1.
This air-conditioning unit contains uorinated greenhouse gasses. For specic information
on the type of gas and the amount, please refer to the relevant label on the unit itself or the
“Owner's Manual - Product Fiche ” in the packaging of the outdoor unit. (European
Union products only).
2.
Installation, service, maintenance and repair of this unit must be performed by a certied
technician.
3.
Product uninstallation and recycling must be performed by a certied technician.
4.
For equipment that contains uorinated greenhouse gases in quantities of 5 tonnes of CO2
equivalent or more, but of less than 50 tonnes of CO2 equivalent, If the system has a leak-
detection system installed, it must be checked for leaks at least every 24 months.
5.
When the unit is checked for leaks, proper record-keeping of all checks is strongly
recommended.
Amount of refrigerant
to be charged (kg) maximum installation
height (m)
Minimum room
area (m²)
2.048 1.8m 4
2.048 0.6m 35
2.048-3.0 1.8m 8
2.048-3.0 0.6m 80
>3.0 1.8m 9
>3.0
Model
(Btu/h)
30000
30000
30000-48000
30000-48000
>48000
>48000 0.6m 80
Cautions for using R32/R290 refrigerant
onnecting piping(when connecting indoors). Use of pipes, areless nut or are nuts other
than specied, may cause product malfunction, burst piping, or injury due to high internal
pressure of the refrigerant cycle caused by any inow air.
Appliance shall be installed, operated and stored in a room with a oor area larger than
X m² (Please see the following form ). The appliance shall not be installed in an
unventilated space, if that space is smaller than X m² (Please see the following form ).
8.
Page 9
Indoor Unit Parts And Major Functions 2
Unit Parts
Air inlet
Air outlet
Fig. 2.1
Operating Conditions
Use the system under the following temperatures for safe and effective operation. If the air
conditioner is used under different conditions, it may malfunction or become less efcient.
Display panel
COOL mode HEAT mode DRY mode
Room Temperature 17°C - 32°C
(63°F - 90°F)0°C - 30°C
(32°F - 86°F) 10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C(32°F - 122°F)
-15°C - 30°C(5°F - 86°F)
0°C - 50°C(32°F - 122°F)
0°C - 52°C(32°F - 126°F)
(For special tropical
models)
(For special tropical
models)
0°C - 52°C(32°F - 126°F)
-15°C - 50°C(5°F - 122°F)
(For models with low
temp. cooling systems.)
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.
Inverter Split Type
COOL Mode HEAT mode DRY mode
Indoor Temperature 17°-32°C (63°-90°F) O°-30°C (32°-86°F) 10°-32°C (50°-90°F)
Outdoor
Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
11°-43°C (52°-109°F)
18°-43°C (64°-109°F)
-7°-43°C (19°-109°F)
(low temperature cooling models)
18°-52°C (64°-126°F)
(For special tropical models)
18°-52°C (64°-126°F)
(For special tropical models)
Fixed-speed Type
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V5MFI32-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V5MFI32-60 in the language / languages: English as an attachment in your email.

The manual is 20.26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor V5MFI32-60

Inventor V5MFI32-60 Additional guide - English - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info