686155
20
Zoom out
Zoom in
Previous page
1/27
Next page
(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/16/2017
329
PO
SAVE THESE INSTRUCTIONS
English
Page 20
MAINTENANCE
IMPORTANT
Unplug the power cord before cleaning your system. Also close the plunger
valves on your pool or insert the black hat-like plugs in the strainer opening to
prevent water spillage. After completing all maintenance tasks, you must plug the
power cord back in and open the plunger valves or remove the plugs.
Flow Sensor Cleaning
1
. In a counter-clockwise motion unscrew the collar of the flow sensor
(6)
and remove it from
the electrolytic cell conduit. See “Part Reference”.
2
. If deposits and debris are seen on the surface of the flow sensor, then use a garden hose
to wash it off.
3
. If flushing with water does not remove the deposits, use a plastic brush to clean the
surface and the hinge if necessary. Do not use a metal brush.
4
. After the flow sensor has been inspected and cleaned, align the locator notch on the flow
sensor to the connection ridge in the conduit. Now turn the collar in a clockwise motion,
tightening the sensor back into its position. Do not overtighten.
Titanium and E.C.O. Electrodes Cleaning
The titanium electrode and E.C.O. electrodes have
a self cleaning function incorporated into
the electronic control’s programming. In most cases this self cleaning action will keep the
electrodes working at optimum efficiency. If the pool water is hard (high mineral content) the
electrodes may require periodic manual cleaning. To maintain maximum performance, we
recommend that you open and visually inspect the titanium and E.C.O. electrodes
(4 & 5)
monthly.
The following steps provide instructions on how to clean your cell.
Inspection and cleaning:
1
. Switch off the unit, unplug the power cord from the electrical socket.
2
.
For filter pumps with 1-1/4” (32mm) hose size
-
To prevent water from flowing out of the
pool, unscrew the strainer grids from the strainer connectors and insert the hat-like plugs
into the strainer connectors.
For filter pumps with 1-1/2” (38mm) hose size -
Turn both plunger valve handles fully
clockwise until they stop. This closes the valve, prevents the water from flowing out of the
pool.
Connection Ridge
Locator Notch
Hinge
20


Need help? Post your question in this forum.

Forumrules
1

Forum

intex-eco-6110

Reset search

  • I have ECO 6110 and keep getting error 91. Have too much salt 6.5 mpp but shows as low salt (that's how too much salt was put in)do I need a new eco electrode or titanium electrode. Or both or a new system? It is about 4years old Submitted on 26-5-2022 at 20:27

    Reply Report abuse
  • Have model eco6100 the working and boost lights are on but no codes in red led box just a dot system will not shut off and no fault lights are shown what is the problem Submitted on 31-5-2021 at 02:34

    Reply Report abuse
  • Yeah I have an Intex model eco6110 is there a sensor that tells how much salt there is the level and which one is it is it the ECO OR the titanium because I keep getting low salt codelite and the water is pretty salty help Submitted on 21-7-2020 at 04:12

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex ECO 6110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex ECO 6110 in the language / languages: English as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info