686155
18
Zoom out
Zoom in
Previous page
1/27
Next page
(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/16/2017
329
PO
SAVE THESE INSTRUCTIONS
English
Page 18
OPERATION INSTRUCTIONS (continued)
6
.
Boost cycle
First time installation, press and hold “BOOST” button for 5 seconds
until the indicator lights up and the LED display “80”. This indicates
that the saltwater system has started E.C.O. and more chlorine
sanitizer production. You can press and hold the “BOOST” button for
another 5 seconds until the indicator is off, which will cancel the Boost
cycle.
The boost operating hours is 8 times the amount of time programmed into the system, i.e. if
your saltwater system operating time is 2 hours, the boost procedure will run 8 x 2 = 16 hours.
After boost procedure has been completed, the system will automatically switch to the
normal working mode.
Once the boost is operating, check whether the filter pump operating hours have been
set properly. For example, the boost operating time is 8 hours, the filter pump should be
set to run for 8 hours at least. Increase the filter pump operating time if necessary.
Note:
If an Intex filter pump is attached to the system, set the pump switch to on “I”
position.
After a heavy rain or if the pool is dirty, press the “BOOST” button to
shock the pool again.
7
.
Stand-by/power saving mode:
When the cycle ends, the green “SLEEP” indicator on the control
panel lights up and the LED display flashes “93”. The system is now
in Stand-By mode. After a while, it shuts down and sets itself in a
Power Saving mode. The system will automatically turn itself back
on in 24 hours, starting its daily cycle of chlorine production.
The “SLEEP” indicator stays on, while the system is in the Power
Saving mode. The LED display however, goes blank after 5 minutes.
Press any button (
or ) to view the last LED code.
8
.
Electrode Self-Clean cycle:
Press and hold button for 5 seconds until the LED display flashes
“10”. Depending on your pool water calcium hardness level, press
button again to select the self-clean cycle time as below. Total of 3
settings: 14 hours, 10 hours and 06 hours.
NOTE:
The life of the cell varies depending on water conditions, pool usage and
operating time of the device. Select 14 hours cycle time to maximize the life of the
electrolytic cell if the calcium hardness level is up to 150 ppm. Manual routine cleaning
and maintenance will further lengthen the life of the electrolytic cell.
With the desired self-clean hours showing, press
button to lock the keypad controls
and the LED display will return to the normal operating time. The system will reverse the
polarity of the electrode
(5)
every time according to the selected hours.
NOTE:
If you forget to lock the keypad controls, the system will automatically lock it and
start working 5 seconds later.
Calcium Hardness Self-clean cycle time
0 - 150 ppm Reverse polarity every 14 hours
150 - 250 ppm Reverse polarity every 10 hours
250 - 350 ppm Reverse polarity every 06 hours
18


Need help? Post your question in this forum.

Forumrules
1

Forum

intex-eco-6110

Reset search

  • I have ECO 6110 and keep getting error 91. Have too much salt 6.5 mpp but shows as low salt (that's how too much salt was put in)do I need a new eco electrode or titanium electrode. Or both or a new system? It is about 4years old Submitted on 26-5-2022 at 20:27

    Reply Report abuse
  • Have model eco6100 the working and boost lights are on but no codes in red led box just a dot system will not shut off and no fault lights are shown what is the problem Submitted on 31-5-2021 at 02:34

    Reply Report abuse
  • Yeah I have an Intex model eco6110 is there a sensor that tells how much salt there is the level and which one is it is it the ECO OR the titanium because I keep getting low salt codelite and the water is pretty salty help Submitted on 21-7-2020 at 04:12

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex ECO 6110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex ECO 6110 in the language / languages: English as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info