801046
10
Zoom out
Zoom in
Previous page
1/20
Next page
10
GB
INN-303 STEAM STERILIZER 4 IN 1
MAIN FUNCTIONS
• Sterilizer: the unit sterilizes baby bottles, rubber
teats and small accessories resisting to high tem-
peratures.
• Baby bottle warmer
• Baby food jar warmer
• Fruits and vegetables steam cooking
• Defrosting function
IMPORTANT ADVISES BEFORE USING
THE APPLIANCE
WARNING: in order to prevent skin burns, you
must never open the sterilizer lid or the steam co-
ver while the product is on. Never put your hand
or ngers inside the steam cover hole.
In order to avoid skin burns, before proceeding
with the product cleaning, it is necessary to let
the unit cooling down for about 20 minutes.
Between every 20 minutes usage, it is necessary
to let the unit cooling down for 20 minutes.
N.B. In case in the last product usage, the ste-
aming cycle (of any function) was interrupted
unplugging the unit from the mains, when you
plug the unit again, the LED is automatically ON
and the product starts functioning immediately
(that it is to say, without pressing the ON button).
STERILIZER
Place the product base (1) on a at and stable
surface.
Insert the racket (10 or 10 a) inside the sterilizer
container (11), following the guides inside the
container.
Racket 10 can hold up to 6 standard baby bottles
(upside down) and small accessories; racket 10a
can hold up to 5 non-standard baby bottles. In case
you should sterilize non-standard baby bottles or
other containers, please remove the racket and
insert the object directly inside the container (11)
Note: before sterilizing any object, it is necessary
to wash and rinse them carefully.
Pour 90ml water (2 x 45cc measuring cups) in the
water bowl (4), using the measuring cup (3 a).
Note: 90ml of water grants a sterilizing cycle of 15
minutes.
Put the container with the units to be sterilised
inside, on the product base; close the container
with its lid (9).
Connect the main unit (1) to the mains.
Switch on the device by sliding “ON/OFF switch
(13) to “ON” position.
Press the ON switch (2) downwards; the LED lights
up (5) and the sterilizing cycle starts.
IMPORTANT. Beware of hot steam from the
steam vent.
Sterilizing cycle lasts about 15 minutes (90ml of
water); once the water inside the water bowl has
ended the main unit stops functioning and the
LED switches itself o.
To end sterilization prematurely, slide ON/OFF
switch (13) to “OFF” position.
BEWARE! Switch the device o after every
sterilization procedure by sliding “ON/OFF”
switch to “OFF”. This stops appliance being
started accidentally.
Unplug the unit from the mains.
In order to avoid skin burns, before removing the
baby bottles and accessories from the container
please wait some minutes.
BABY BOTTLE WARMER
Place the product base (1) on a at and stable
surface.
Pour 45ml water (1 measuring cup) in the water
bowl (4), using the measuring cup (3 a).
Note:
- 45ml of water grants a warming cycle of 7 minutes.
- 90ml of water grants a warming cycle of 15 minutes.
Place the racket (12) on the product base (1) and
close with the steam cover (7); for standard baby
bottles, please add the adaptor ring (8)
In order to improve the product performance, it
is advisable to add the adaptor ring for standard
baby bottles. In case of non-standard baby bot-
tles please do not use the adaptor ring.
Insert the baby bottle inside the steam cover.
Connect the main unit (1) to the mains.
Switch on the device by sliding “ON/OFF switch
(13) to “ON” position.
Press the ON switch (2) downwards; the LED lights
up (5) and the warming cycle starts.
Warming cycle lasts about 7/8 minutes (45ml of
water); once the water inside the water bowl has
ended the main unit stops functioning and the
LED switches itself o.
To end sterilization prematurely, slide ON/OFF
switch (13) to “OFF” position.
Beware! Switch the device o after every steri-
lization procedure by sliding “ON/OFF” switch
to “OFF”. This stops appliance being started
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innoliving INN-303 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innoliving INN-303 in the language / languages: English, Italian as an attachment in your email.

The manual is 0.29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info