Product errors and troubleshooting
Problem
Item to detect
Solution
Battery depleted
Replace old batteries with new
ones
Batteries have been installed
with the wrong polarity
Batteries are not installed
properly
Take out the batteries and re-
install them correctly.
Unable to carry out
measurement as current battery
capacity is too low.
Replace the batteries
Measurement distance too long
Target temperature is beyond
range of measurements
Environment temperature either
exceeds the design range or is
unstable
Follow the instruction manual
and repeat the measurements
Current state: All symbols are
flashing on the screen. The
product is not usable.
Please contact customer
services.
Body temperature
Body temperature runs approximately from 35.5-37.8 (95.9°F to100°F). To
determine if one has a fever, compare the temperature detected with the
person's normal temperature. A rise over the reference body temperature of
1(1°F) or more is generally an indication of fever.
Different measurement sites (rectal, axillary, oral, frontal, auricular) will give diff-
erent readings. Therefore, it is wrong to compare the measurement taken from
different sites.
The following are typical temperatures for adults, based on different
measurement sites:
Rectal
97.9°F-99.1°F
36.6 to 38
Axillary
94.5°F-99.1°F
34.7 to 37.3
Oral
95.9°F-99.5°F
35.5 to 37.5
Auricular
96.4°F-100.4°F
35.8 to 38
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for iHealth PT2L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of iHealth PT2L in the language / languages: English as an attachment in your email.

The manual is 0.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of iHealth PT2L

iHealth PT2L User Manual - German - 16 pages

iHealth PT2L User Manual - French - 15 pages

iHealth PT2L User Manual - Spanish - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info