InstallatIon
In general
Congratulations on your new HWAM woodburning stove. We are pleased that you have chosen a HWAM
woodburning stove and confident that it will give you much pleasure. To ensure optimum operation and
safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a
fitter recommended by the retailer. For an overview of HWAM distributors, visit www.hwam.com under
“Retailer locations”.
Safety
The installation of your HWAM woodburning stove must always comply with all European, national and
local building regulations. The installation must be carried out in accordance with the instructions in the
installation and user manuals and subsequently registered with the local authorities. Upon installation,
the chimney sweep must approve the installation before you can start using the woodburning stove. All
HWAM stove packaging material must be handled in accordance with local waste management regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed. The
woodburning stove uses approx. 6-23 m
3
of air per hour (depending on the setting of the air control
lever). A window that can be opened or an adjustable air valve will be sufficient. It must not be possible
to block the adjustable air valve/grate. In newly built/airtight dwellings, we recommend that a fresh air
system should be installed for the direct supply of external air to the combustion. This fresh-air system
may be bought separately.
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand
the weight of the stove and the chimney. The weight of the chimney should be calculated according to
its dimensions and height.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the woodburning stove should be kept from glass.
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect 4.5 kW
Flue gas temperature EN 13240 measurement point 254ºC
Flue gas temperature measured in the outlet socket 300ºC
Exhaust gas flow 5.1 g/s
Efficiency 78.1%
Annual efficiency 68.1%
PM 22 mg/m3
OGC 85 mg/m3
NOx 130 mg/m3
CO at 13% O
2 875 mg/m3
CO at 13% O
2 0.07 %
Energy efficiency index 103
Energy efficiency class A
Test result based on NS 3058
Particle emissions 2.05 g/kg
The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.
EnglIsh
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 3740 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 3740 in the language / languages: English as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 3740

Hwam 3740 User Manual - German - 20 pages

Hwam 3740 User Manual - Dutch - 20 pages

Hwam 3740 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info