Model Weight Height Width Depth
HWAM 3520c/3520m 118/115 kg 126,0 cm 54,0 cm 37,1 cm
HWAM 3520c/3520m, natural stone cladding 155/152 kg 127,0 cm 54,0 cm 37,1 cm
HWAM 3520c/3520m, soapstone cladding 167/164 kg 127,0 cm 54,0 cm 37,1 cm
Heat storage stones, HWAM 3520 44 kg
Floor plate
European, national and local regulations must be observed in terms of the size and thickness of a non-
combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM
retailer for assistance. The combustion chamber opening is 34.0 cm wide.
Distance to combustible materials
Min. distances - uninsulated flue gas pipe (drawing A) HWAM 3520
1. Recommended for brick wall 10 cm
1. For combustible back wall 10 cm
2. For combustible side wall 20 cm
1.To combustible wall,corner installation, 45º 13 cm
3. Distance to furnishings in front 80 cm
Remember to pay attention to the applicable regulations concerning the required distance
between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM® SmartControlTM..
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a combustible wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance. As a general
rule, satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80
cm above the ridge. If the chimney is placed at side walls, the top of the chimney should always be higher
than the ridge or the tallest point of the roof. Always be aware of any national and/or local regulations
applying to thatched roofs and the location of the chimneys.
The stove requires a minimum draught of 12 Pa (measured at EN 13240 measurement point). If measured
just above the smoke flue socket, the chimney draught must be 18-20 Pa.
The chimney must have a minimum clearing of Ø 150 mm. The chimney must be provided with an
easily accessible cleaning door. The chimney and flue duct must be of flue class T400 and be CE marked.
Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to
combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer
for further information.
Changing the smoke outlet from top outlet to back outlet - HWAM 3520 (drawing D)
For stoves suitable for stone cladding (without stone cladding installed), begin with item 3 and end after
item 16.
1. Removing sides. Lift one side about 10 mm and pull it away from the stove so that it disengages from
the guide pins on the bottom plate of the stove. Repeat on the other side.
2. Removing the top plate (1). Remove the four screws (Torx Bit no. 30 or M6 nut) beneath the top plate,
two on each side, and lift the top plate off.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 3520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 3520 in the language / languages: English as an attachment in your email.

The manual is 1.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 3520

Hwam 3520 User Manual - English - 56 pages

Hwam 3520 User Manual - German - 44 pages

Hwam 3520 User Manual - Dutch - 32 pages

Hwam 3520 User Manual - Danish - 56 pages

Hwam 3520 User Manual - French - 32 pages

Hwam 3520 User Manual - Italian - 44 pages

Hwam 3520 User Manual - Swedish - 56 pages

Hwam 3520 User Manual - Spanish - 44 pages

Hwam 3520 User Manual - Norwegian - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info