624653
12
Zoom out
Zoom in
Previous page
1/48
Next page
Page 9
FUNDAMENTALS OF
WATER MAINTENANCE
Testing: Test the water weekly or each time the spa is used with
convenient FRESHWATER 5-way test strips or more accurate liquid/
tablet reagent test kit per instructions. Critical parameters: sanitizer
level, pH, Calcium Hardness (CH), and Total Alkalinity (TA). Store test
equipment in a dark, cool, dry place to maintain potency.
Water Filtration: The 100% no by-pass 24 hour filtration used in HOT
SPRING spas provides the best approach to keeping water clean
by constantly circulating sanitizer and removing waste from the spa.
Regularly inspect and clean filters for peak performance.
Chemical Balance/pH Control: It is important to adjust the primary
water parameters (Total Alkalinity, Calcium hardness, pH) into the
recommended ranges so
that they are stabilized or
balanced. Balance the
water chemistry every time
you fill the spa with new
water and then during the
life of that body of water.
Keeping the water in
balance prevents damage
by holding the pH in a
safe range and preventing
calcium scale formation
on spa equipment. A low
pH can damage metal
components whereas a
high pH can cause high levels of calcium to form scale. Your dealer
should provide a detailed water chemistry orientation soon after your
new spa is filled for the very first time.
The following three water components must be kept in balance to avoid
damage to the spa. Do balance these components in the order they
are listed here as each will help you balance the next using a minimum
amount of chemicals.
1. Calcium Hardness (CH) – CH is the measure of the amount
of dissolved calcium in the water. Low levels can make the
water corrosive and high levels cause scale formation of spa
components. The recommended CH reading is between
50 - 150 ppm. A hardness of 50 ppm is recommended with
the ACE System. If the CH level is too low, raise it with
FRESHWATER Calcium Increaser, and if the CH level is too
high, lower it with the VANISHING ACT calcium remover per
instructions. Once in balance, the CH reading normally remains
stable until new water is added. Great care must be taken when
filling the spa from a water softener to ensure that the calcium
remains in balance and avoid damage to the spa.
2. Total Alkalinity (TA) - TA is a measure of the water’s ability to
resist changes of pH or buffer capacity. A low TA allows the pH
to fluctuate easily. The recommended TA reading is between
40 - 120 ppm. To raise the TA, use FRESHWATER pH/
Alkalinity Up (sodium hydrogen carbonate). To lower the TA, use
FRESHWATER pH/Alkalinity Down (sodium bisulfate). Once the
TA is balanced, it normally remains stable until the next drain/
refill. We recommend you check the TA reading once per month.
Raising/lowering the TA may cause the pH readings to fluctuate
widely. Ignore the pH readings on the test strip while you are
balancing the TA.
3. pH - The pH is the measure of the acidity and alkalinity.
Maintaining the proper pH level will optimize the effectiveness of
the sanitizer, preventing damage to the spa and physical discomfort
for spa users. A low pH dissipates sanitizer, causes corrosion,
and irritates spa users. A high pH level will neutralize sanitizer,
promote scaling and cloud water. The recommended pH reading
is between 7.2 - 7.6. To lower the pH level, use FRESHWATER
pH/Alkalinity Down (sodium bisulfate). To raise the pH level, use
FRESHWATER pH/Alkalinity Up (sodium carbonate).
Water Conditioners: Spa fill water varies from location to location and
user to user, therefore it is important to consult with your dealer for an
appropriate program.
a. VANISHING ACT – High levels of calcium and some minerals
can be removed from the water with the single use VANISHING
ACT. High calcium levels can cause scale formation on the spa
equipment and shell.
b. CLEAN SCREEN pre-filter –The CLEAN SCREEN pre-flter
should be used at every fill and top-off to remove contaminants
from the fill water, especially iron, copper, and manganese. Many
water sources including well water contain high concentrations of
minerals that can cause staining of the shell and plastics.
c. Stain and Scale control – For water high in calcium and minerals,
it may be necessary to use an anti-scalant like Stain and Scale
control. As water evaporates from your spa and new water is
added, the amount of dissolved minerals like calcium, copper, iron,
and manganese will increase. (Minimize evaporation by keeping
the cover on the spa whenever possible.) High iron or copper
content in the water may produce green or brown stains on the spa.
d. Foam Inhibitors - Soap is introduced into the spa water from users’
bodies and swimming apparel and can cause the spa water to
foam when the jets are used. Low levels of calcium hardness (soft
water) can increase foaming. Although ozone and ACE can oxidize
soap residual, it may become necessary to add Foam Inhibitors
to suppress the foam. Excessive soap in the water may require a
water change to resolve.
Oxidizers: Ozone and Monopersulfate (MPS) are oxidizers used to
prevent the buildup of contaminants, maximize sanitizer efficiency,
minimize combined chlorine, and improve water clarity. They are to be
used in conjunction with EPA registered sanitizers. The FRESHWATER
III high output ozone system uses Corona Discharge technology to
produce a high concentration of ozone which is injected into the spa
water 24 hours per day. FRESHWATER Chlorine-Free Oxidizer,
Monopersulfate (MPS) is a granular oxidizing chemical.
Sanitizers: Maintaining the recommended residual level of an EPA
registered sanitizer at all times will decrease the occurrence of unsafe
bacteria and viruses in your spa water. The recommended Free
Available Chlorine (FAC), the amount of available chlorine sanitizer,
is 3.0-5.0 ppm. A low FAC can allow bacteria and viruses to grow
rapidly in the warm water, and a high FAC can cause discomfort to the
user’s eyes, lungs, and skin. Each sanitizer carries its own instructions
regarding how much to use and when to add it to the spa water.
Consult your dealer for their recommendations and instructions on
proper sanitizing of the spa.
a. ACE Salt Water Sanitizing System
b. EVERFRESH
Water Care System FRESHWATER Concentrated
Chlorinating Granules
c. Sodium Dichloro-s-Triazinetrione (sodium dichlor or chlorine)
d. Brominating Concentrate (one step granular bromine).
e. BaquaSpa
®
(please consult your BAQUASPA manual for
instructions on the use of this product).
ALKALINE
SPA
WATER
(SCALING
ZONE)
ADD pH
DECREASER
TO LOWER
pH
ADD pH
INCREASER
TO RAISE
pH
ACIDIC
SPA
WATER
(CORROSIVE
ZONE)
COMFORT
ZONE
IDEAL
Water Quality and Maintenance
12


Need help? Post your question in this forum.

Forumrules
1

Forum

hot-spring-prodigy---h

Reset search

  • I have a 2001 prodigy and the circulation pump doesn’t seem to come on. And now cold weather the jets poor out very cold water. What could this be? Submitted on 18-10-2022 at 15:54

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hot Spring PRODIGY - H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hot Spring PRODIGY - H in the language / languages: English as an attachment in your email.

The manual is 6,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info