Connecting the mains lead4.4
Mains connection is made directly at the plug terminal to the
transformer via the NYY underground cable (see Figure 2.4).
Follow the safety instructions in Electrical connection on
page 25.
Fitting the print bracket4.5
Fasten the print bracket using the two screws loosened 1.
earlier
B
, as well as two additional screws from the
scope of delivery (see Figure 2.5).
Re-plug the connecting terminals.2.
Fitting the magnet bracket4.6
Push the gate by hand into the 1. CLOSE end-of-travel
position.
Fully preassemble the supplied magnet slide in the centre 2.
position (see Figure 2.6).
Install the toothed track clip on the toothed track in such 3.
a manner that the magnet is positioned opposite the reed
contact in the print bracket of the operator housing,
offset by approx. 20 mm, when the gate is closed.
NOTE:
If you are unable to push the gate easily into the required
CLOSE end-of-travel position, check the gate mechanics for
use with the sliding gate operator (Safety instructions for
fitting, page 22).
Locking the operator4.7
The operator is engaged once locked. The motor must f
be slightly raised when the mechanism is turned to the
lock position (see Figure 3).
4.8 Electrical connection
DANGER
Dangerous electrical voltage
Mains voltage is necessary for operating this device.
Improper use can cause electrical shocks which can lead to
death or serious injuries.
Electrical connections may only be made by a qualified f
electrician.
Always disconnect the operator from the power supply f
before performing any work on the gate system.
The on-site electrical installation must comply with the f
respective safety regulations.
All the cables must be inserted into the control unit f
from below and free from distortion.
CAUTION
Damage to the electronics caused by external voltage
External voltage on the connecting terminals of the control
will destroy the electronics.
Lay the operator cables in an installation system that is f
separate from the mains supply.
If laying cables in the ground, use an underground f
cable (NYY) (see Figure 1).
Connecting standard components4.9
Mains connection is made directly at the plug terminal to the
transformer via the NYY underground cable (see Figure 2.4).
Connecting additional components/accessories4.10
The total consumed current may be max. 500 mA when
connecting accessories at the following terminals:
24 V=• SE3/LS•
Ext. radio• SE1/SE2•
Connecting an external radio receiver*4.10.1
See f Figure 4.1
(*Accessory, not included as standard equipment!)
The wires of the external radio receiver should be f
connected as follows:
GN to terminal 20 (0 V)
WH to terminal 21 (channel 1 signal)
BN to terminal 5 (+24 V)
YE to terminal 23 (channel 2 signal for partial
opening). Only with a 2-channel receiver.
NOTE:
The aerial wire of external radio receivers should not come
into contact with metal objects (nails, bracing, etc.). The best
orientation to achieve an optimum range must be established
by trial and error. When used at the same time, GSM 900
mobile phones can affect the range of the radio remote
control.
Connecting external buttons*4.10.2
See f Figure 4.2
(*Accessory, not included as standard equipment!)
One or more buttons with normally open contacts (volt-free),
e.g. key switches, can be connected in parallel, max. lead
length 10 m.
Impulse control
First contact to terminal f 21
Second contact to terminal f 20
Partial opening:
First contact to terminal f 23
Second contact to terminal f 20
NOTE:
If auxiliary voltage is needed for an external button, then a
voltage of +24 V DC is available for this at terminal 5 (against
terminal 20 = 0 V).
TR10A059-C RE / 10.2008 25
ENGLISH
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hormann Schuifhekaandrijving at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hormann Schuifhekaandrijving in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 7,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info