565055
5
Zoom out
Zoom in
Previous page
1/16
Next page
5
Securing the radiator controller
i
The radiator controller and the batteries can be
secured against removal by using the supplied
screws.
Setting the position of the display
In order to improve the legibility the display of the
radiator controller can be tilted to different positions
(10°, 20°, 30°, 40°).
The angle of 40° can be fixed with the supplied display
support.
1.
2.
Mounting
1. Lift the display and set it to the desired angle.
2. If desired, tilt the display by 40° and slide the display
support from above between the display and the
housing until it latches in.
Unmounting
fPress the display support in at the back and remove
it upwards.
Connecting optional sensors and window
contact
The following external sensors and window contacts can
be connected to the HR90 radiator controller:
HCW23 setpoint adjuster
RF20 room sensor
HCA30 floating window contact
i
The ACS90 cable is required to connect external
sensors and the window contact.
Micro B mini-plug / open ends
2 m long
Not included in the scope of delivery
Operation with HCW23 setpoint adjuster
The room temperature is measured by the
HCW23 setpoint adjuster. The HR90 internal room
temperature sensor is not used in this particular
application. The adjustment dial of the HCW23 can be
used to change the room temperature ±12 K as an offset
to the temperature set/programmed at the HR90. The
offset setting remains valid until it is changed again.
Operation with RF20 room sensor
The room temperature is measured by the external
RF20 room sensor. The HR90 internal room temperature
sensor is not used in this particular application.
Operation with window contact
When the window is opened, the window contact is
opened and the radiator valve closes. When the window
is closed again, the radiator controller returns to normal
operation.
The frost-protection function ensures that the radiator
valve opens when the temperature drops below 5 °C.
i
When de-installing a connected room sensor RF20
or room unit HCW23, remove the batteries and
insert them again to avoid error messages.
When de-installing the window contact, change
parameter 17 to 1 or 0, see section 9.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell TheraPro HR90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell TheraPro HR90 in the language / languages: English as an attachment in your email.

The manual is 5,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell TheraPro HR90

Honeywell TheraPro HR90 User Manual - German - 16 pages

Honeywell TheraPro HR90 User Manual - Dutch - 16 pages

Honeywell TheraPro HR90 Quick start guide - All languages - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info