Galaxy 2 Series Installation Manual
2 = Access Mode
This option determines what authorisation is required for remote service connection. There are two options:
1 = Direct Access
This permits access anytime. The remote centre can dial directly to the panel and gain access. If a call-back
number is programmed in option 3, then connection must be made by the call back procedure.
2 = Manager Authorise
This requires the user to authorise the remote servicing call via menu 47. The panel will not answer an incom-
ing call without authorisation.
3 = Callback No.
Remote servicing software requests the Galaxy 2 Series to call back the programmed telephone number.
4 = Downloader ID
This option specifies an eight-digit ID number for panels communicating via the remote servicing software.
This option defaults to 99999999. This is a security number and cannot be viewed at the keypad.
17 = SMS Paging
As a secondary alarm notification to keyholders, facility for sending SMS messages to a maximum of 3 mobile
phones, is incorporated. This comms format will only transmit once any Primary signalling programmed, has
successfully completed or has finished all redial attempts.
The panel dials the message centre number and leaves a message for each of the mobile phone numbers
programmed, according to the selected event type groups.
If a call is being made to an SMS centre number and a new event occurs which needs to be sent to the main
alarm reporting station, the call to the SMS centre number will be completed normally before the primary
number is dialled.
The following table lists the event types for this option:
Table 27. Event Types
56 - Comms (cont’d)
epyTstnevE
1stnevemralA
2teSdnamralA
3tluaFdnamralA
4stnevEllA
For each of the above events, the full text event log entry for each event, including the additional info display, is
sent as an SMS message. Note that for alarm activations, only the first two alarm activations in each set
period will be sent. This will be reset at rearm.
If a kiss-off is not received, the system redials for two minutes. These redials are within 5-10 seconds of the
previous call. There is no comms fail fault condition generated if the calls are not successful, but an SMS fail
event is logged.
Where SMS has been programmed to send via both the PSTN and GSM modules, the panel will always try
and send using the GSM module. The PSTN module will be backup only.
97


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell Galaxy 2 Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell Galaxy 2 Series in the language / languages: English as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell Galaxy 2 Series

Honeywell Galaxy 2 Series User Manual - Dutch - 20 pages

Honeywell Galaxy 2 Series Usermanual and installation guide - Dutch - 148 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info