742508
7
Zoom out
Zoom in
Previous page
1/144
Next page
7
EN
Before first switch-on
For safety reasons, it is recommended that the wa-
ter installation of the device is vented before the
first switch-on. In order to do so, water inlet to the
softener must be shut off. Consecutively, the sam-
pler valve after the water softener must be opened,
whereas the mains valve of the building shall be
opened gently. Water flowing will push air out
through the open sampler valve. A bubbling sound
will appear and water may gush. One shall wait un-
til the flow of water stabilizes and then close the
sampler valve. The system is now vented.
Venting. Filling water into the device
In order to vent the device, the sampler valve after
the water softener must be opened, whereas the
mains valve of the building shall be opened gently.
Then, one shall proceed as in the case of venting
the entire system. It is recommended that the de-
vice is filled with water gradually, with breaks, in
order not to increase pressure inside the device
abruptly.
ATTENTION! The salt tank must be filled with salt and water before the first switch-on of
the device. One shall wait 30 minutes before salt dissolves in water. Resin regeneration
must then be performed.
First resin regeneration (ONLY 230459 model)
Regeneration must be activated with the usage of the manual regeneration button. Regeneration will
be done automatically. After it finishes, the device is ready to operate.
Operating cycles of the device
In serve the device is in the position of the first operation cycle, i.e. water treatment. Water
flows though the device. Raw water enters the container with resin through the
controller, flows through the resin and is directed upwards, through a distribution
pipe, to the controller and further to the system.
BACKWASH
The device is in the position of the second operation cycle - anti-current rinse
(backwash). Raw water enters the container with the filter bed through an inlet valve and
is directed downwards with a central pipe. Water flows through the resin, rinses it and
fluffs it, and then is directed to sewage. In this cycle the controller shuts off water inlet
to the water system. Thanks to which the controller protects the water system against
the penetration of impurities from rinsing.
BRINE DRAW SLOW RINSE T
he device in the position of third operation cycle - regeneration with brine and slow
rinsing. Raw water with brine enters to the container with the filter bed through an inlet
valve. Flowing through the bed in the tank, it regenerates its ion exchange capacity. After
flowing through the bed, water is directed to sewage. After all brine in the brine tank is
used up, the ion exchange bed is rinsed slowly with water, which guarantees thorough
rinsing brine and proper regeneration conditions. In this cycle the controller shuts off
water inlet to the water system. Thanks to which the controller protects the water
system against the penetration of impurities from rinsing.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hendi 230442 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hendi 230442 in the language / languages: English, German, Dutch, French, Italian, Polish as an attachment in your email.

The manual is 1,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info